Always reliable switching and controlling

Switching and Control

Semiconductor contactors have proven themselves in industrial applications everywhere high switching frequencies or high switching cycles are required. With their long service lives and wear-free switching, they handle switching and controlling tasks in specific applications in a highly economical manner.

 

Safety technology is becoming more and more important in machine and equipment construction. Safety modules or even safety controllers are being used everywhere. Despite the increasing use of semiconductors, electromechanical relays remain an important component of such systems. The have the task of switching loads and galvanically separating electrical circuits. Classical applications, particularly for relays with mechanical force-guided contacts, are in the monitoring of emergency stop switches, safety doors or light barriers, for example. They are also essential in railway signalling equipment as well as in the controllers for passenger and goods elevators as well as in medical equipment. Our PCB relays are available in a great variety of different contact variants and construction forms and guarantee the highest switching safety with minimal dimensions.

Download

Solid-state relay / contactor PH 9260

• AC semiconductor relay / -contactor
• According to IEC/EN 60947-4-3
• Load current up to 125 A, AC 51 with I2t up to 18000 A2s
• Switching at zero crossing
• As option switching at voltage maximum
• 2 anti-parallel thyristors
• DCB technology (direct bonding method) for excellent
heat transmission properties
•...

Download

Solid-state relay / contactor with load circuit monitoring PH 9270

• AC semiconductor relay /-contactor
• With integrated load circuit monitoring
• Settable load limit value
• According to IEC/EN 60947-4-3
• Load current 40 A, AC 51
• Switching at zero crossing
• 2 anti-parallel thyristors
• DCB technology (direct bonding method) for excellent
heat transmission properties
•...

Download

Solid-state relay / contactor for resistive load PK 9260

• AC semiconductor relay / -contactor
• PK 9260/_ _ _ according to IEC/EN 62314
PK 9260/_ _ _ / _ _ according to IEC/EN 60947-4-2 and -4-3
• Load current up to 88 A, AC-51
• Switching at zero crossing for resistive loads
• 2 anti-parallel thyristors
• DCB technology (direct bonding method) for excellent
heat transmission...

Download

Solid state contactor BF 9250

• According to IEC/EN 60 947-4-2, IEC/EN 60 947-4-3
• 1-, 2- and 3-pole models
• Load current up to 50 A
• For AC load up to 480 V
• Switching at zero crossing
• Protected by varistors
• As option temperature protection of the power semiconductors
with monitoring output
• Mounting on DIN-rail
• As option with...

Download

Solid-state contactor with current monitoring BH 9251

• According to IEC/EN 60 947-1, IEC/EN 60 947-4-2
• Switching at zero crossing
• To switch single-phase AC load up to 400 V
• Compensates voltage fluctuations of ± 20 %
• Load current up to 40 A
• Monitors:
- Undercurrent
- Overcurrent
- Interrupted load circuit
- monitors temperature to protect the power semiconductor
•...

Download

Safety relays OA 5623

• According to DIN EN 61810-1, DIN EN 61810-3
• With forcibly guided contacts
• Clearance and creepage distances:
contact - contact ≥ 5,5 mm
• Low rated power consumption and holding power
• High mechancial service life
• High temperature range
• High thermal continuous current
• Height: 15.8 mm

Download

Bistable relay OB 5623

• According to DIN EN 61810-1, DIN EN 61810-3
• With forcibly guided contacts
• Energy efficient; Low energy consumption, because of impulse control,
no holding consumption
• Bistable
Mechanical latching of contact position
• Safe separation between all current circuits
• Both coils non-polarised, neutral
• Defined...

Download

Safety relays OA 5642

• According to DIN EN 61810-1, DIN EN 61810-3,
DIN EN 45545 (fire protection on railway vehicles)
• With forcibly guided contacts
• Safe separation betwenn coil/contact and contact/contact for
applications at pollution degree 2 with rated insulation voltage 250 V
• Clearance and creepage distances
contact - coil ≥ 5.5 mm
contact -...

Download

Safety relays OA 5643

• According to DIN EN 61810-1, DIN EN 61810-3,
DIN EN 45545 (fire protection on railway vehicles)
• With forcibly guided contacts
• Safe separation betwenn coil/contact and contact/contact for
applications at pollution degree 2 with rated insulation voltage 250 V
• Clearance and creepage distances
contact - coil ≥ 5.5 mm
contact -...

Download

Safety relays OA 5644

• According to DIN EN 61810-1, DIN EN 61810-3,
DIN EN 45545 (fire protection on railway vehicles)
• With forcibly guided contacts
• Safe separation betwenn coil/contact and contact/contact for
applications at pollution degree 2 with rated insulation voltage 250 V
• Clearance and creepage distances
contact - coil ≥ 5.5 mm
contact -...