Dold Industries Ltd

11 Hamberts Rd. Blackall Ind. Estate
South Woodham Ferrers
GB-Essex, CM3 5UW
UF 6925

Emergency stop module

UF 6925

Contacts

Nominal voltage

Approval

Variant

  • 0067556
  • UF6925.03/61 DC8-36V
The emergency stop module UF 6925 is suitable to protect men and machine by safety related... more

Product description

The emergency stop module UF 6925 is suitable to protect men and machine by safety related enabling or disabling of a safety circuit. It is used in applications with e-stop buttons and safety gates.

Technical specifications

Width: 17,5 mm
Type: UF 6925
Cross fault detection: +
Thermal current Ith max.: 8 A
SIL CL acc. to IEC/EN 62061: 3
Approvals: UL
1- / 2-channel: 2
Connection: Federkraftklemmen
Also suited as safety gate monitor: +
Output contacts max.: 3 Schließer
Cat. / PL acc. to EN ISO 13849-1: 4/e
Nominal voltage DC: +

Advantages

  • For safety applications up to PL e / Cat. 4 e.g. SIL 3
  • Space saving
  • Connection front side
  • Manual or automatic start
  • Can be used also for safety gate
  • Line fault detection on On-button

Features

  • According to
    - Performance Level (PL) e and category 4 to EN ISO 13849-1
    - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
    - Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
  • According to EN 50156-1 for furnaces
  • 2-channel operation
  • Forcibly guided output contacts
  • With or without cross fault monitoring in the E-stop loop, switch S1
  • Manual restart or automatic restart, switch S2
  • LED indicator for channel 1, 2 and Netz
  • Width 17,5 mm