This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
"Allow all cookies" cookie
"Decline all cookies" cookie
CSRF token
Cookie preferences
Currency change
Customer recognition
Customer-specific caching
Individual prices
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Statistics & Tracking
Affiliate program
Google Tag Manager
Track device being used

Standstill monitor
UG 6946
- Article number: 0068410
- Variant: UG6946.02PS/001 20-400mV 0,2-6s
Safe standstill detection on 3- and single-phase motors, e.g. to enable gate interlocks on... more
Product description
Safe standstill detection on 3- and single-phase motors, e.g. to enable gate interlocks on machine tools or to activate hold in brakes.
Technical specifications
Thermal current Ith max.: | 5 A |
Function: | Stillstandswächter |
Type: | UG 6946 |
Cat. / PL acc. to EN ISO 13849-1: | 4/e |
Width: | 22,5 mm |
1- / 2-channel: | 2 |
SIL CL acc. to IEC/EN 62061: | 3 |
Measuring motor voltage max.: | 690 V |
Forcibly guided output contacts max.: | 1 ö, 2 s |
Downloads
Advantages
- Without sensor and safe
- Fast reaction time
- Easy to retrofit
- Combined with Interlock SAFEMASTER STS
- Protection against manipulation by sealable transparent cover over setting switches
Features
- According to
- Perf. Level (PL) e and category 4 to EN ISO 13849-1, EN 61800-5-2
- SIL-Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508, IEC/EN 61511 and EN 61800-5-2 - Safe standstill detection on 3- and single-phase motors
- No external sensors necessary
- Independent of direction
- Broken wire detection
- Forcibly guided safety contacts:
- 2 NO contacts for AC 250 V
- 1 NC contact for DC 24 V - Adjustable voltage setting
- Adjustable standstill time delay
- LED indicators for standstill, event of line breakage and operation voltage
- Suitable for operation with inverters
- Removable terminal strips:
- UG 6946 PS: plug in screw terminals
- UG 6946 PC: plug in cage clamp terminals - Variant /_ _1:
- Possibility of bridging the speed monitoring (muting) - Width: 22.5 mm