In the automotive industry in particular, the increasing globalization of the markets is forcing manufacturers to respond ever faster and more flexibly to the customers’ individual requirements. To meet this challenge, vehicle manufacturers are focusing on core components such as vehicle bodies and drive systems. Vehicle production is performed with the system components from the suppliers and using sophisticated logistics concepts. Intelligent automation and the smooth running of the production processes are of critical importance here.

Download

Radio controlled safety module BI 6910

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• Safety radio transmission
• Radio receiver for:
- Radio controlled enabling switch
- Control signals for 6 non-safety semiconductor outputs
• Multifunction safety modul with additional control input to connect:
- E-stop pushbutton (2-channel), safety gate or LC type 4
according to EN 61496
- 1 Start button
- 1 or 2 monitoring contacts to signal the use of radio
• Adjustable functions with step switch for:
- Manual start or automatic start
- when removing the enabling switch from the charger (open
control contact) manual start is possible by enabling switch
- possibility of disabling the access protection (gate) with active
enabling switch
• Broken wire and short circuit monitoring with error indication
• Feedback circuit Y1/Y2 for monitoring of exernal contactors
• 2 semiconductor outputs for status indication
• LEDs for status indication
• Easy connection
• DIN rail mounting
• Removable terminal blocks allow fast exchange of module
• Also as input modul for multifunction, modular safety system
SAFEMASTER M available
• Compact unit, only 67.5 mm width

Download

Insulation monitor RN 5897/010

• Insulation monitoring according to IEC/EN 61557-8
• With connection facility of an external coupling device RP 5898
for voltages up to 1000 V
• Trigger output for insulation fault locating system
• 2 separate adjustable response thresholds
(using e.g. for pre-Alarm and Alarm)
• Setting range of 1st response value (Pre-Alarm): 20 kΩ … 2 MΩ
• Setting range of 2nd response value (Alarm): 1 kΩ … 250 kΩ
• 2 changeover contacts für insulation failures-Pre-Alarm and -Alarm
• Energized or de-energized on trip can be selected for indicator relay
• Display for indication of measured value, device parameters and
device status
• Setting the maximum leakage capacitance to shorten the response time
• Automatic and manual device self-test
• Alarm storage selectable
• Protection against manipulation by sealable transparent cover
• External control input for combined Test-/Reset-button
• 3 wide voltage input for auxiliary voltage
• Width 52.5 mm

Download

Speed monitor UH 6932

• According to
- Performance Level (PL) e und category 4 to EN ISO 13849-1: 2008
- SIL-Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
- Safety Integrity Level (SIL) 3 to IEC/EN 61511
• Overspeed, underspeed or window monitoring
• Integrated user friendly frontside display
- Comfortable, menu guided configuration
- For set point and actual value of Hz
• Fast reaction time by measuring duration of cycle of input frequency
• For PNP- or NPN-sensors
• Adjustable hysteresis
• Adjustable reset delay function from 0 ... 100 s
• Adjustable start up time delay from 0 ... 100 s
• Adjustable alarm delay from 0.1 ... 100 s
• Manual or auto-reset
• 2-channel function
• Forcibly guided output contacts
• LED-indicators and 2 semiconductor monitoring output
• Width 45 mm
• With pluggable terminal blocks for easy exchange of devices
• Variant /_ _1:
- it is possible to set a variety of response parameters by means of a
4 bit selection facility from an overriding control unit;
- analog output (2 V to 10 V) corresponding to the current speed;
- the possibility of overriding the speed by a
supervisory function (muting);
- adjustable switchover time from 0 ... 100 s

Download

Radio controlled enabling switch RE 6910

• Radio controlled enabling switch RE 6910 for BI 6910
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• Safety radio transmission
• User friendly, compact enabling switch for
radio controlled safety modul BI 6910
• programmable for
- Command mode with 4 command buttons or
- Function mode with max. 10 functions and 2 command buttons each
• with LCD-display to indicate the function settings,
battery charging, transmitting e.g.
• Indications of the function settings can be uploaded as „bitmap“
• Protection against unintentional activation
• Speed charging and high battery capacity
• Fast change of frequency
• Pocket for remote control as option

Download

Switch with separat actuator and forced key removal STS-SX01BM/K

The unit is particularly suitable for applications with:
• Full body access (lock-in danger)
• Several secured entries
• Single-channel/ redundant/ diverse safety circuits
• Rugged ambient conditions

Download

Speed and frequency monitor UH 6937

• According to
- Performance Level (PL) e und category 4 to EN ISO 13849-1
- SIL-Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
- Safety Integrity Level (SIL) 3 to IEC/EN 61511
• Over-, underfrequency or window monitoring of single or
3-phase in AC systems
• Integrated user friendly frontside display
- Comfortable, menu guided configuration
- For set point and actual value of Hz
• Fast reaction time by measuring duration of cycle of input frequency
• Universal measuring inputs for AC-voltages of 8 ... 280 V for
single-phase monitoring as well as 16 ... 690 V for
single- and 3-phase monitoring
• Suitable for inverters
- Variant /0_ _ : 1 ... 700 Hz
- Variant /1_ _ : 1 ... 1200 Hz
• Adjustable hysteresis
• Adjustable reset delay function from 0 ... 100 s
• Adjustable start up time delay from 0 ... 100 s
• Adjustable alarm delay from 0.1 ... 100 s
• Manual or auto-reset
• galvanic separation between measuring input, auxiliary voltage and
output contacts
• 2-channel function
• Forcibly guided output contacts
• LED-indicators and 2 semiconductor monitoring output
• Width 45 mm
• With pluggable terminal blocks for easy exchange of devices
• Variant /_ _1:
- it is possible to set a variety of response parameters by means of a
4 bit selection facility from an overriding control unit;
- analog output (2V to 10V) corresponding to the current speed;
- the possibility of overriding the speed by a
supervisory function (muting);
- adjustable switchover time from 0 ... 100 s

Download

Residual current monitor, Type B RN 5883

• According to IEC/EN 62 020, VDE 0663
• For AC and DC systems Type B, according to IEC/TR 60755
• To detect earth faults in grounded voltage systems
• 4 setting ranges from 10 mA to 3 A
• Manual reset, with alarm and pre-warning
• With adjustable switching delay
• Energized or de-energized on trip
• LED indicator for operation, pre-alarm and alarm
• With test function
• LED-chain indicates fault current
• As option with analogue output
• Broken wire detection
• Width: 52.5 mm

Download

Switch with separat actuator and forced key removal STS-SX01A

The unit is particularly suitable for applications with:
• Full body access (lock-in danger)
• Several secured entries
• Single-channel/ redundant/ diverse safety circuits
• Rugged ambient conditions

Your agents


    Competence on site

    Damit wir für Sie Ihren persönlichen Ansprechpartner finden können, geben Sie bitte die fünfstellige Postleitzahl Ihres Ortes in das Suchfeld ein.

    Agents for: