Solutions for semiconductor applications

Semiconductor applications

Ever higher switching frequencies are demanded in many industrial applications, whether it be for heating controls, hot glue robots or conveyor devices. As a result, productivity can be increased and quality improved. At the same time, switching devices are marked by a long service life. This ensures high plant availability and low service costs. All of these are important criteria for the competitiveness of machinery and systems. Here, semiconductor relays and contactors come into their own. Integrated monitoring functions for preventative maintenance also offer further potentials for improving efficiency.

Download

Solid state relay PH 9260

• AC semiconductor relay / -contactor
• According to IEC/EN 60947-4-3
• Load current up to 125 A, AC 51 with I2t up to 18000 A2s
• Switching at zero crossing
• As option switching at voltage maximum
• 2 anti-parallel thyristors
• DCB technology (direct bonding method) for excellent
heat transmission properties
• Touch protection IP20
• Box terminals
• LED status indicator
• Peak reverse voltage 1200 V or 1600 V
• Insulation voltage 4000 V
• As option with overtemperature protection
• As option with reduced HF-emission
• As option with heat sink, for DIN rail mounting
• Width: 45 mm

Download

Solid state relay / contactor PH 9260.92

• AC semiconductor relay / -contactor
• According to IEC/EN 60947-4-3
• As option load current up to 2 x 32 A or 2 x 48 A
• As option with hight I²t up to 6600 A²s
• Load voltages up to AC 480 V
• 2 anti-parallel thyristors for each pole
• DCB technology (direct bonding method) for excellent
heat transmission propertie
• Touch protection IP20
• Box terminals for load connections
• LED status indicator for both poles
• Peak reverse voltage up to ± 1200 V
• Insulation voltage 4000 V
• Width 45 mm

Download

Solid state relay / contactor with load circuit monitoring PH 9270

• AC semiconductor relay /-contactor
• With integrated load circuit monitoring
• Settable load limit value
• According to IEC/EN 60947-4-3
• Load current 40 A, AC 51
• Switching at zero crossing
• 2 anti-parallel thyristors
• DCB technology (direct bonding method) for excellent
heat transmission properties
• Two-colours LED status indicator
• Touch protection IP20
• PLC compatible alarm output (PNP; NPN on request)
• As option closed circuit operation or open circuit operation
• As option with optimized heat sink, for DIN rail mounting
• Width 45 mm

Download

Solid state relay / contactor with load current measurement PH 9270/003

• AC semiconductor relay /-contactor with load current measurement
(runs value)
• Analogue output DC 0 ... 10 V
• According to IEC/EN 60947-4-3
• Nominal voltage up to AC 240 V
• Load current up to 45 A, AC-51
• Switching at zero crossing
• DCB technology (direct bonding method) for excellent
heat transmission properties
• LED indicator for control
• As option with optimized heat sink, for DIN rail mounting
• Width: 45 mm

Download

Solid state relay / contactor for ohmic loads PK 9260

• AC semiconductor relay / -contactor
• PK 9260/_ _ _ according to IEC/EN 62314
PK 9260/_ _ _ / _ _ according to IEC/EN 60947-4-2 and -4-3
• Load current up to 88 A, AC-51
• Switching at zero crossing for resistive loads
• 2 anti-parallel thyristors
• DCB technology (direct bonding method) for excellent
heat transmission properties
• As option with:
- M4 flat terminal or
- M5 screw terminal for cable lug
• LED status indicator
• Peak reverse voltage up to ± 1600 V
• Insulation voltage 4000 V
• As option with heat sink, for DIN rail mounting

Download

Solid state contactor BF 9250

• According to IEC/EN 60 947-4-2, IEC/EN 60 947-4-3
• 1-, 2- and 3-pole models
• Load current up to 50 A
• For AC load up to 480 V
• Switching at zero crossing
• Protected by varistors
• As option temperature protection of the power semiconductors
with monitoring output
• Mounting on DIN-rail
• As option with control input X1 with low current consumption
e.g. to be controlled by a PLC
• As option up to 3 separate semiconductor contactors in one unit
• BF 9250: width 22.5 mm, 45 mm and 90 mm
BH 9250: width 45 mm, 67.5 mm and 112.5 mm

Download

Solid state contactor BF 9250/_ _8

• According to IEC/EN 60 947-4-2, IEC/EN 60 947-4-3
• 1-, 2- and 3-pole versions
• Load current up to 50 A at TU = 40° C
• For AC load up to 530 V
• Switching at zero crossing, optionally immediate switching
• Protected by varistors
• Mounting on DIN-rail
• Widths: 22.5 mm, 45 mm and 90 mm

Download

Solid state contactor with temperature monitoring BF 9250/001

• According to IEC/EN 60 947-4-2, IEC/EN 60 947-4-3
• 1-, 2- and 3-pole models
• Load current up to 50 A
• For AC load up to 480 V
• Switching at zero crossing
• Protected by varistors
• As option temperature protection of the power semiconductors
with monitoring output
• Mounting on DIN-rail
• As option with control input X1 with low current consumption
e.g. to be controlled by a PLC
• As option up to 3 separate semiconductor contactors in one unit
• BF 9250: width 22.5 mm, 45 mm and 90 mm
BH 9250: width 45 mm, 67.5 mm and 112.5 mm

Download

Solid state contactor with temperature monitoring BF 9250/002

• Analogue controller for accurate process temperature control
• Burst firing control of heaters
• Control input optional with DC 0 ... 10 V, DC 4 ... 20 mA, 0 ... 10 kΩ
• Reverse action operation possible
• Rated operational voltage range up to 480 V
• Rated operational current is up to AC 50 A
• Zero cross switching
• Protected by varistors
• Temperature protection of the power semiconductors
• LED indications for supply, output status and alarm status
• Alarm indication on mains synchronisation failure
• Alarm indication on control input failure
• Alarm indication on over temperature of power semiconductors
• DIN-rail mountable
• BF 9250/0_2 to 10 A: Width 22.5 mm
BF 9250/0_2 to 25 A: Width 45 mm
BF 9250/0_2 to 50 A: Width 90 mm

Download

Solid state contactor with burst control BF 9250/042

• Analogue controller for accurate process temperature control
• Burst firing control of heaters
• Control input optional with DC 0 ... 10 V, DC 4 ... 20 mA, 0 ... 10 kΩ
• Reverse action operation possible
• Rated operational voltage range up to 480 V
• Rated operational current is up to AC 50 A
• Zero cross switching
• Protected by varistors
• Temperature protection of the power semiconductors
• LED indications for supply, output status and alarm status
• Alarm indication on mains synchronisation failure
• Alarm indication on control input failure
• Alarm indication on over temperature of power semiconductors
• DIN-rail mountable
• BF 9250/0_2 to 10 A: Width 22.5 mm
BF 9250/0_2 to 25 A: Width 45 mm
BF 9250/0_2 to 50 A: Width 90 mm

Download

Solid state contactor BH 9250

• According to IEC/EN 60 947-4-2, IEC/EN 60 947-4-3
• 1-, 2- and 3-pole models
• Load current up to 50 A
• For AC load up to 480 V
• Switching at zero crossing
• Protected by varistors
• As option temperature protection of the power semiconductors
with monitoring output
• Mounting on DIN-rail
• As option with control input X1 with low current consumption
e.g. to be controlled by a PLC
• As option up to 3 separate semiconductor contactors in one unit
• BF 9250: width 22.5 mm, 45 mm and 90 mm
BH 9250: width 45 mm, 67.5 mm and 112.5 mm

Download

Solid state contactor with load circuit monitoring BH 9251

• According to IEC/EN 60 947-1, IEC/EN 60 947-4-2
• Switching at zero crossing
• To switch single-phase AC load up to 400 V
• Compensates voltage fluctuations of ± 20 %
• Load current up to 40 A
• Monitors:
- Undercurrent
- Overcurrent
- Interrupted load circuit
- monitors temperature to protect the power semiconductor
• De-energized on fault
• One relay output with changeover contact
• LED Indicators
• No auxiliary supply
• Galvanically separated control input X1-X2 with wide voltage range
• Adjustable current response value
• With integrated heat sink
• DIN-rail mounting
• 45 mm, 67.5 mm and 112.5 mm width
Approvals and Marking
Applications
• Data sheet BF 9250, Semiconductor contactor
Additional Information about this topic