Solutions for Energy technology

Energy technology

You know the situation: complex production systems, high requirements in terms of the quality, delivery time and reliability, permanent cost pressure. This requires more than ever a comprehensive operational readiness in order to be able to maintain and improve the competitiveness at the international level. In practice, however, a comprehensive operational readiness is often given only conditionally, because insulation faults may slowly but progressively occur due to ageing, moisture, pollution, mechanical damage and other factors. Consequences of such undiscovered errors are costly plant shut-downs and operational downtime, repair costs and usually high costs resulting from production downtime. In the worst case these insulation faults are even a frequent cause of fires and personal injuries.

Download

Voltage and frequency monitor RP 9800

• According to DIN EN 60255-1, DIN EN 60947-1
• Voltage and frequency monitoring for generator sets >30 kVA
on public grid, according to VDEW directive
• RP 9800: 3-phase voltage measurement to neutral
• Disconnection on rise and drop of voltage
• Disconnection on rise and drop of frequency
• Disconnection when 10 minute...

Download

Insulation monitor RN 5897/010

• Insulation monitoring according to IEC/EN 61557-8
• Trigger output for insulation fault locating system
• 2 separate adjustable response thresholds
(using e.g. for pre-Alarm and Alarm)
• Setting range of 1st response value (Pre-Alarm): 20 kΩ … 2 MΩ
• Setting range of 2nd response value (Alarm): 1 kΩ...

Download

Multifunction Measuring Relay MK 9300N

• Multifunction measuring relay acc. to EN 60255-1
• Voltage monitoring (1- and 3-phase)
• Current monitoring
• Frequency monitoring
• Power factor cos phi
• Phase sequence, phase failure, asymmetry
• Effective-, reactive- and apparent power
• Start up delay, on delay
• Adjustable hysteresis 0.2 ... 50 % of...

Download

Voltage and frequency monitor acc. to VDE-AR-N 4105 RP 9810

• Certificate of conformity (test certificate) of the BG ETEM
acc. to VDE-AR-N 4105
• Following DIN V VDE V 0126-1-1
• According to DIN EN 60 255-1
• Can be used according to EEG 2012 and SysStabV
• Voltage and frequency monitoring for generator sets >30 kVA on
public grid, as option also for ≤ 30kVA
• Fail-safe because...

Download

Voltage and frequency monitor RP 9811

• Certificate of conformity (test certificate) of the BG ETEM
• Acc. to VDE-AR-N 4105, DIN VDE 0126-1-1, BDEW-directive,
CEI-0-21
• Acc. to DIN EN 60 255-1
• Can be used according to EEG 2012 and SysStabV
• Voltage and frequency monitoring for generator sets
• Fail-safe 2-channel structure
• Monitoring of the section...

Download

Insulation monitor LK 5896

• Insulation monitoring according to IEC/EN 61557-8
• Detection of symmetric and asymmetric insulation faults
• Measuring circuits can be disconnected via control terminals, e.g. for mains couplings
• 1 changeover contact each for prewarning and alarm
• 3. output relay for signalling wire break and device faults
•...

Download

Residual current monitor, Type B RN 5883

• According to IEC/EN 62 020, VDE 0663
• For AC and DC systems Type B, according to IEC/TR 60755
• To detect earth faults in grounded voltage systems
• 4 setting ranges from 10 mA to 3 A
• Manual reset, with alarm and pre-warning
• With adjustable switching delay
• Energized or de-energized on trip
• LED indicator...

Download

Insulation monitor LK 5895

• Insulation monitoring according to IEC/EN 61557-8
• Detection of symmetric and asymmetric insulation faults
• Measuring circuits can be disconnected via control terminals, e.g. for mains couplings
• 1 changeover contact each for prewarning and alarm
• Prewarning threshold setting range: 20 kΩ ... 2 MΩ
• Alarm...

Download

Insulation monitor LK 5894

• Insulation monitoring according to IEC/EN 61557-8
• Detection of symmetric and asymmetric insulation faults
• 2 changeover contacts
• Prewarning threshold setting range: 20 kΩ ... 2 MΩ
• Alarm threshold setting range: 1 kΩ ... 250 kΩ
• Energized or de-energized on trip can be selected for output...

Download

Phase monitor IL 9087

• According to IEC/EN 60 255, VDE 0435, DIN VDE 0660 part 302
(pr EN 60 947-8) and part 303
• Monitoring of phase failure
- Undervoltage 3-phase 3 or 4 wire
- Phase failure
- Phase sequence
- Loss of neutral
- Phase asymmetry
• Without auxiliary supply
• De-energized on trip
• LED indication
- Supply voltage
- Phase failure
• 1 or...

Download

Over- and undervoltage relay IL 9077

• According to IEC/EN 60 255, DIN VDE 0435-303
• Identification of overvoltage, undervoltage and phase failure
• With asymmetry identification as an option
• Mains fault diagnostics with a number of LEDs
• Setting values for overvoltage and undervoltage can be set
separately
• Large Setting Ranges 0.9 ... 1.3 UN and 0.7 ......

Download

Undervoltage Relay IL 9171

• According to IEC/EN 60 255-1
• Monitoring of undervoltage in 3-phase system
• Also for single phase
• Without auxiliary supply
• Optionally for 3p3w systems
• LED indicator for state of output relay
• Independent of phase sequence
• 1 or 2 changeover contacts
• Optionally fixed or settable response value
•...