Solutions for renewable energy

Renewable energy

Whether they provide photovoltaic, wind or water power, the number of power generation plants using renewable energy continues to grow. The operators of these plants attach great importance to efficiency and economy. Only by means of proper system solutions for the control and monitoring of power generation can competitive efficiency be achieved. Only a high level of efficiency can create the economic basis for replacing electricity from fossil fuels. In addition, it is important that safety-related issues are considered.

Download

Smart motorstarter UG 9256

• According to IEC/EN 60 947-4-2
• To reverse 3 phase motors up to 550 W to 4 kW
• 2-phase softstart
• max. 4 potentiometer für setting of starting torque, deceleration torque,
softstart /-stop, overcurrent limit or rated motor current
• 4 LEDs for status indication
• Reversing with relays without current, softstart, softstop with thyristor
• Galvanic separated 24V-inputs for clockwise- and anticlockwise
• Reset button on front
• Connection facility for external reset button
• Relay indicator output for operation
• Indicator output at customers specification (on request)
• Galvanic separation between control circuit and power circuit
• Width: 22,5 mm

Download

Latching relay MK 8852

• According to IEC/EN 61 810-1
• Setting input A1 - A2
• Reset input A3 - A2
• Storage function
• Switch position indication
• Manual operation
• Width 22.5 mm

Download

Insulation monitor RN 5897/010

• Insulation monitoring according to IEC/EN 61557-8
• With connection facility of an external coupling device RP 5898
for voltages up to 1000 V
• Trigger output for insulation fault locating system
• 2 separate adjustable response thresholds
(using e.g. for pre-Alarm and Alarm)
• Setting range of 1st response value (Pre-Alarm): 20 kΩ … 2 MΩ
• Setting range of 2nd response value (Alarm): 1 kΩ … 250 kΩ
• 2 changeover contacts für insulation failures-Pre-Alarm and -Alarm
• Energized or de-energized on trip can be selected for indicator relay
• Display for indication of measured value, device parameters and
device status
• Setting the maximum leakage capacitance to shorten the response time
• Automatic and manual device self-test
• Alarm storage selectable
• Protection against manipulation by sealable transparent cover
• External control input for combined Test-/Reset-button
• 3 wide voltage input for auxiliary voltage
• Width 52.5 mm

Download

Locating current injector RR 5886

• Insulation troubleshooting in DC, AC and mixed IT systems in connection with the insulation fault locator RR 5887 according to DIN EN 61557-9 (VDE 0413-9):2009 and DIN EN 61557-1 (VDE 0413-1)
• Insulation coordination according to IEC 60664-1
• External control via insulation monitor possible
• Positive and negative test current to monitor DC networks and networks with simultaneous alternating current and direct current portions present
• RS-485 bus connection to synchronise the test current analysis and optionally for the connection to the EDS measuring bus
• Control via insulation monitor via RS-485 bus or external control input possible
• Pushbutton for manual test current output
• Terminal connection for automatic test current output
• Status output of insulation fault detection via external switching output
• Width: 105 mm

Download

Voltage and frequency monitor acc. to VDE-AR-N 4105 RP 9810

• Certificate of conformity (test certificate) of the BG ETEM
acc. to VDE-AR-N 4105
• Following DIN V VDE V 0126-1-1
• Can be used according to EEG 2012 and SysStabV
• Voltage and frequency monitoring for generator sets >30 kVA on
public grid, as option also for ≤ 30kVA
• Fail-safe because of 2-channel structure
• Certificate of conformity (test certificate) of the BG ETEM
• Monitoring of the section switches with measuring of response time
• System test via test button
• Isolated grid detection
• Manual reset
• With additional enabling input, e.g. for ripple control receiver
• Connection or re-connection after adjustable delay time tw
• Factory setting according to VDE-AR-N 4105
• Random controlled disconnection in the range of 50.2 Hz and 51.5 Hz
for non-regulated power generation systems
• Protection against manipulation by sealable transparent cover
over setting switches
• Additional fault signalling relay output
• High measuring accuracy
• Installion type enclosure 4TE (width x height x depth: 70 x 90 x 71 mm)

Download

Latching relay AD 8851

• According to IEC/EN 61 810-1
• Manual operation possible
• Contact position indication via control lever
• max. 4 NC contacts, 4 NO contacts
• Width 45 mm

Download

Insulation monitor RN 5897/300

• Insulation monitoring according to IEC/EN 61557-8
• 2 separate adjustable response thresholds
(using e.g. for pre-Alarm and Alarm)
• Setting range of 1st response value (Pre-Alarm): 20 kΩ … 1 MΩ:
• Setting range of 2nd response value (Alarm): 10 kΩ … 250 kΩ
• 2 changeover contacts für insulation failures-Pre-Alarm and -Alarm
• Energized or de-energized on trip can be selected for indicator relay
• LED for status indication
• Automatic and manual device self-test
• Alarm storage selectable
• Protection against manipulation by sealable transparent cover
• External control input for combined Test-/Reset-button
• 3 wide voltage input for auxiliary voltage
• Width 52.5 mm

Download

Insulation fault locator RR 5887

• Insulation troubleshooting in DC, AC and mixed IT systems in connection with the locating current injector RR 5886 according to DIN EN 61557-9 (VDE 0413-9):2009 and DIN EN 61557-1
(VDE 0413-1)
• Insulation coordination according to IEC 60664-1
• Connection of max. 4 or 8 differential current transformers depending on the design
• RS-485 bus connection to synchronise the test current output and optionally for the connection to the EDS measuring bus for reading insulation fault currents
• Status output of insulation fault detection via external switching output
• Memory characteristics adjustable via bridge Y1-Y2
• Collective signalling relay to output preliminary warning and alarm states
• Pushbutton for manual reset of alarm states as well as testing of differential current transformers and their calibration
• Terminal connection for the storage of alarm states
• Width: 105 mm

Download

Voltage and frequency monitor RP 9811

• Certificate of conformity (test certificate) of the BG ETEM
acc. to VDE-AR-N 4105, DIN VDE 0126-1-1, BDEW-directive,
CEI-0-21
• Can be used according to EEG 2012 and SysStabV
• Voltage and frequency monitoring for generator sets
• Fail-safe 2-channel structure
• Monitoring of the section switches by measuring the response time
• System test via test button
• Enabling inputs allow integration into various ripple control and plant
concepts
• Isolated grid detection
• Manual reset
• Memorising of disconnection time
• Connection or re-connection after adjustable delay time tOn
• Factory setting according to:
VDE-AR-N 4105, DIN VDE 0126-1-1, BDEW-directive, CEI 0-21,
ÖVE/ÖNORM, G59/3 LV
• Random controlled disconnection in the range of 50.2 Hz and 51.5 Hz
for non-regulated power generation systems
• Random operated connection time (ton) setting range 60...600 s
• Additional fault signalling relay output
• High measuring accuracy
• Installion type enclosure 4TE (width x height x depth: 70 x 90 x 71 mm)

Download

Insulation monitor LK 5896

• Insulation monitoring according to IEC/EN 61557-8
• Detection of symmetric and asymmetric insulation faults
• Measuring circuits can be disconnected via control terminals, e.g.
for mains couplings
• 1 changeover contact each for prewarning and alarm
• 3. output relay for signalling wire break and device faults
• Prewarning threshold setting range: 20 kΩ ... 2 MΩ
• Alarm threshold setting range: 1 kΩ ... 250 kΩ
• Energized or de-energized on trip can be selected for output relay
• Setting the maximum leakage capacitance to shorten the response time
• Simple, clearly arranged adjustment of the device with screwdriver
• LED chain to indicate the current insulation resistance
• Display of active measuring circuits
• Automatic and manual device self-test
• Alarm storage selectable
• External test and reset pushbutton can be connected
• Width: 90 mm

Download

Insulation monitor LK 5895

• Insulation monitoring according to IEC/EN 61557-8
• Detection of symmetric and asymmetric insulation faults
• Measuring circuits can be disconnected via control terminals, e.g.
for mains couplings
• 1 changeover contact each for prewarning and alarm
• Prewarning threshold setting range: 20 kΩ ... 2 MΩ
• Alarm threshold setting range: 1 kΩ ... 250 kΩ
• Energized or de-energized on trip can be selected for output relay
• Setting the maximum leakage capacitance to shorten the response time
• Simple, clearly arranged adjustment of the device with screwdriver
• LED chain to indicate the current insulation resistance
• Display of active measuring circuits
• Automatic and manual device self-test
• Alarm storage selectable
• External test and reset pushbutton can be connected
• Width 90 mm

Download

Insulation monitor LK 5894

• Insulation monitoring according to IEC/EN 61557-8
• Detection of symmetric and asymmetric insulation faults
• 2 changeover contacts
• Prewarning threshold setting range: 20 kΩ ... 2 MΩ
• Alarm threshold setting range: 1 kΩ ... 250 kΩ
• Energized or de-energized on trip can be selected for output relay
• Setting the maximum leakage capacitance to shorten the response time
• Simple, clearly arranged adjustment of the device with screwdriver
• LED chain to indicate the current insulation resistance
• Display of active measuring circuits
• Automatic and manual device self-test
• Width: 90 mm