Solutions for airports

Airports

Control and monitoring solutions at airports ensure that many logistics processes run smoothly. They guarantee that everything ends up where it belongs – the airplanes at their designated parking positions, the air cargo containers on the correct flights, and the passengers' baggage in the right hands. Control and monitoring solutions can be found in many applications, both in baggage and air cargo logistics and passenger boarding bridges, as well as in monitoring systems for buildings and open spaces.

Download

Radio controlled safety module UH 6900

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• Machine directive 2006/42/EG
• DIN EN 574: Safety of machinery - Two-hand control devices -
• DIN EN 300 220: Electromagnetic compatibility and...

Download

Locating current injector RR 5886

• Insulation troubleshooting in DC, AC and mixed IT systems in connection with the insulation fault locator RR 5887 according to DIN EN 61557-9 (VDE 0413-9):2009 and DIN EN 61557-1 (VDE 0413-1)
• Insulation coordination according to IEC 60664-1
• External control via insulation monitor possible
• Positive and negative test current...

Download

Insulation monitor RN 5897/010

• Insulation monitoring according to IEC/EN 61557-8
• With connection facility of an external coupling device RP 5898
for voltages up to 1000 V
• Trigger output for insulation fault locating system
• 2 separate adjustable response thresholds
(using e.g. for pre-Alarm and Alarm)
• Setting range of 1st response value (Pre-Alarm):...

Download

Insulation fault locator RR 5887

• Insulation troubleshooting in DC, AC and mixed IT systems in connection with the locating current injector RR 5886 according to DIN EN 61557-9 (VDE 0413-9):2009 and DIN EN 61557-1
(VDE 0413-1)
• Insulation coordination according to IEC 60664-1
• Connection of max. 4 or 8 differential current transformers depending on the design
•...

Download

Softstarter with soft coasting UH 9018

• Softstart with softstop
• For motors from 1.5 kW to 7.5 kW
• 2-phase control
• Adjustable ramp time, starting torque and starting voltage
• Kickstart-(Boost-)function
• DIN-rail mounting
• Width: 45 mm

Download

Residual current monitor, Type B RN 5883

• According to IEC/EN 62 020, VDE 0663
• For AC and DC systems Type B, according to IEC/TR 60755
• To detect earth faults in grounded voltage systems
• 4 setting ranges from 10 mA to 3 A
• Manual reset, with alarm and pre-warning
• With adjustable switching delay
• Energized or de-energized on trip
• LED indicator...

Download

Insulation monitor LK 5894

• Insulation monitoring according to IEC/EN 61557-8
• Detection of symmetric and asymmetric insulation faults
• 2 changeover contacts
• Prewarning threshold setting range: 20 kΩ ... 2 MΩ
• Alarm threshold setting range: 1 kΩ ... 250 kΩ
• Energized or de-energized on trip can be selected for output...

Download

Insulation monitor UH 5892

• Insulation monitoring according to IEC/EN 61557-8
• Detection of symmetric and asymmetric insulation faults
• 1 changeover contact for alarm
• Fixed response value RAN: 50 kΩ, other on request
• Internal reset and test pushbutton
• External test and reset pushbutton can be connected
• LED indicator for auxiliary...

Download

Softstarter with softstop BA 9019

• Increases the life of squirrel cage motors and mechanical drives
• Easily fitted to existing installations
• 2-phase control softstart and softstop
• For motors up to 5.5 kW
• Start current limited to 2 to 3 times rated motor current
• Semiconductors bridged after softstart
• Adjustable ramp time, starting torque and...