Solutions for the railroad industry

Railroad industry

Guaranteed electrical safety and reliable availability represent prerequisites for smooth railroad operations. This applies to locomotives and wagons just as much as to signaling systems, signal boxes, tunnels and bridge constructions. This means that system solutions are needed that ensure the continuous monitoring of electrical equipment and railroad facilities. Besides this, early warnings must enable troubleshooting before critical conditions arise.

Please select required language:

Brochure, Catalog Railway applications, File: pdf, File size 5 MB

Download

Locating current injector RR 5886

• Insulation troubleshooting in DC, AC and mixed IT systems in connection with the insulation fault locator RR 5887 according to DIN EN 61557-9 (VDE 0413-9):2009 and DIN EN 61557-1 (VDE 0413-1)
• Insulation coordination according to IEC 60664-1
• External control via insulation monitor possible
• Positive and negative test current to monitor DC networks and networks with simultaneous alternating current and direct current portions present
• RS-485 bus connection to synchronise the test current analysis and optionally for the connection to the EDS measuring bus
• Control via insulation monitor via RS-485 bus or external control input possible
• Pushbutton for manual test current output
• Terminal connection for automatic test current output
• Status output of insulation fault detection via external switching output
• Width: 105 mm

Download

Insulation monitor RN 5897/010

• Insulation monitoring according to IEC/EN 61557-8
• With connection facility of an external coupling device RP 5898
for voltages up to 1000 V
• Trigger output for insulation fault locating system
• 2 separate adjustable response thresholds
(using e.g. for pre-Alarm and Alarm)
• Setting range of 1st response value (Pre-Alarm): 20 kΩ … 2 MΩ
• Setting range of 2nd response value (Alarm): 1 kΩ … 250 kΩ
• 2 changeover contacts für insulation failures-Pre-Alarm and -Alarm
• Energized or de-energized on trip can be selected for indicator relay
• Display for indication of measured value, device parameters and
device status
• Setting the maximum leakage capacitance to shorten the response time
• Automatic and manual device self-test
• Alarm storage selectable
• Protection against manipulation by sealable transparent cover
• External control input for combined Test-/Reset-button
• 3 wide voltage input for auxiliary voltage
• Width 52.5 mm

Download

Insulation fault locator RR 5887

• Insulation troubleshooting in DC, AC and mixed IT systems in connection with the locating current injector RR 5886 according to DIN EN 61557-9 (VDE 0413-9):2009 and DIN EN 61557-1
(VDE 0413-1)
• Insulation coordination according to IEC 60664-1
• Connection of max. 4 or 8 differential current transformers depending on the design
• RS-485 bus connection to synchronise the test current output and optionally for the connection to the EDS measuring bus for reading insulation fault currents
• Status output of insulation fault detection via external switching output
• Memory characteristics adjustable via bridge Y1-Y2
• Collective signalling relay to output preliminary warning and alarm states
• Pushbutton for manual reset of alarm states as well as testing of differential current transformers and their calibration
• Terminal connection for the storage of alarm states
• Width: 105 mm

Download

Insulation monitor LK 5894

• Insulation monitoring according to IEC/EN 61557-8
• Detection of symmetric and asymmetric insulation faults
• 2 changeover contacts
• Prewarning threshold setting range: 20 kΩ ... 2 MΩ
• Alarm threshold setting range: 1 kΩ ... 250 kΩ
• Energized or de-energized on trip can be selected for output relay
• Setting the maximum leakage capacitance to shorten the response time
• Simple, clearly arranged adjustment of the device with screwdriver
• LED chain to indicate the current insulation resistance
• Display of active measuring circuits
• Automatic and manual device self-test
• Width: 90 mm

Download

Interface module, with plug-type socket HC 3096N

• According to DIN EN 61810-1, IEC 60664-1, IEC/EN 60 947-5-1
• With forcibly guided contacts according to IEC 61810-3
• Models with soldered in or plug-in PCB safety relay consisting of:
- plug in socket HC 3096N and safety relay OA 5611
- plug in socket HL 3096N and safety relay OA 5612
• With polarity protected diode
• Optionally with free-wheeling diode across A1+ and A2
• Optionally AgNi + 0,2 μm Au or AgNi + 5 μm Au
• For DIN rail mounting according IEC/EN 60715
• HC 3096N: width 18 mm
HL 3096N: width 36 mm

Download

Interface module, with plug-type socket HL 3096N

• According to DIN EN 61810-1, IEC 60664-1, IEC/EN 60 947-5-1
• With forcibly guided contacts according to IEC 61810-3
• Models with soldered in or plug-in PCB safety relay consisting of:
- plug in socket HC 3096N and safety relay OA 5611
- plug in socket HL 3096N and safety relay OA 5612
• With polarity protected diode
• Optionally with free-wheeling diode across A1+ and A2
• Optionally AgNi + 0,2 μm Au or AgNi + 5 μm Au
• For DIN rail mounting according IEC/EN 60715
• HC 3096N: width 18 mm
HL 3096N: width 36 mm

Download

Interface relay / input-output IK 3076

• According to IEC/EN 60 255, IEC/EN 61 810-1
• Protective separation according to IEC/EN 61 140,
IEC/EN 60 947-1 in configuration with 1 changeover contact
• With input wiring protection against voltage surges
• With 1 or 2 changeover contacts as options
• High permanent current Ith
• For switching low loads as an option
• LED indicator
• Devices available in 2 enclosure version:
IK 3076: depth 59 mm with terminals at the bottom for
installation systems and industrial distribution systems
according to DIN 43 880
SK 3076: depth 98 mm with terminals at the top for
cabinets with mounting plate and cable duct
• Width 17.5 mm

Download

Insulation monitor IL 5881

• According to IEC/EN 61 557-8
• For DC voltage systems up to 12 ... 280 V
• Wide voltage range of measuring input UN DC 12 ... 280 V (on request DC 24 ... 500 V with separate auxiliary supply, Measuring range 20 ... 500 kΩ) • Adjustable tripping value RAL of
5 ... 200 kΩ
• Selective ground fault indication for L+ and L- allows fast fault finding
• Without auxiliary supply
• De-energized on trip
• 2 changeover contacts
• Automatic or manual reset, programmable
• With test and reset buttons
• Connection for external test and reset button possible
• galvanic separated AC or DC auxiliary supply available as option
• adjustable time delay as option
• 2 models available:
IL 5881: 61 mm deep with terminals near to the bottom to be mounted in consumer units or industrial distribution systems according to DIN 43 880
SL 5881: 98 mm deep with terminals near to the top to be mounted in cabinets with mounting plate and cable ducts
• 35 mm width

Download

Insulation monitor SL 5881

• According to IEC/EN 61 557-8
• For DC voltage systems up to 12 ... 280 V
• Wide voltage range of measuring input UN DC 12 ... 280 V (on request DC 24 ... 500 V with separate auxiliary supply, Measuring range 20 ... 500 kΩ)
• Adjustable tripping value RAL of 5 ... 200 kΩ
• Selective ground fault indication for L+ and L- allows fast fault finding
• Without auxiliary supply
• De-energized on trip
• 2 changeover contacts
• Automatic or manual reset, programmable
• With test and reset buttons
• Connection for external test and reset button possible
• galvanic separated AC or DC auxiliary supply available as option
• adjustable time delay as option
• 2 models available:
IL 5881: 61 mm deep with terminals near to the bottom to be mounted in consumer units or industrial distribution systems according to DIN 43 880
SL 5881: 98 mm deep with terminals near to the top to be mounted in cabinets with mounting plate and cable ducts
• 35 mm width

Download

Interface module with plug-type socket HC 3093

• According to DIN EN 61810
• 2 output contacts with monostable PCB-relay OA 5668
• Version with bistable PCB-relay OB 5694
• Contact material AgNi with fine gold
• High thermal current up to Ith = 16 A with relays
OA 5682 and OB 5694
• Large temperature range: - 40 ... + 85 °C
• As option with free-wheel diode or varistor between A1/A2
• As option with AgSnO2 or AgNi with hard gold
• Width: 15.8 mm