Waterborne traffic is gaining in importance all over the world. Production capacity is being expanded everywhere, both in the fields of passenger and freight transport. This applies both to the number of passenger and container ships, as well as to their size. Some passenger ships now resemble floating cities. A reliable energy supply has to be available in order for their infrastructure to function. The demands on the electrical system are equally high, as are those placed on monitoring and security concepts. At the same time, the speed of turnover is increasing at every port. The associated logistical challenges can only be met by a high plant availability of the ship-to-shore lifting equipment and harbor cranes. Here too, optimizing the electrical equipment provides the level of safety required.

Download

Locating current injector RR 5886

• Insulation troubleshooting in DC, AC and mixed IT systems in connection with the insulation fault locator RR 5887 according to DIN EN 61557-9 (VDE 0413-9):2009 and DIN EN 61557-1 (VDE 0413-1)
• Insulation coordination according to IEC 60664-1
• External control via insulation monitor possible
• Positive and negative test current to monitor DC networks and networks with simultaneous alternating current and direct current portions present
• RS-485 bus connection to synchronise the test current analysis and optionally for the connection to the EDS measuring bus
• Control via insulation monitor via RS-485 bus or external control input possible
• Pushbutton for manual test current output
• Terminal connection for automatic test current output
• Status output of insulation fault detection via external switching output
• Width: 105 mm

Download

Multifunction Measuring Relay MK 9300N

• Multifunction measuring relay acc. to EN 60255-1
• Voltage monitoring (1- and 3-phase)
• Current monitoring
• Frequency monitoring
• Power factor cos phi
• Phase sequence, phase failure, asymmetry
• Effective-, reactive- and apparent power
• Start up delay, on delay
• Adjustable hysteresis 0.2 ... 50 % of response value
• Manual reset
• LCD for indication of the measuring values
• Relay output
MK 9300N: 1 changeover contact
MH 9300: 2 x 1 changeover contacts
• Relay function selectable (energized/de-energized on trip)
• As option with plugable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• MK 9300N: Width 22,5 mm

Download

Residual current monitor, Type A IL 5882

• According to IEC/EN 62 020
• for AC and pulsating DC currants Type A to IEC/TR 60755
• 9 tripping values from 10 mA to 10 A or from 10 mA ... 30 A
• Frequency range 20 ... 2000 Hz
• Selection of manual or automatic reset
• With prewarning
• With test and reset button
• Broken wire detection
• Short reaction time
• With adjustable delay tv
• De-energized on trip
• LED indication for auxiliary supply and state of contact
• 2 x 1 changeover contact
• With sealable cover
• Devices available in 3 enclosure versions:
IL 5882: 63 mm deep with terminals near to the bottom to be
mounted in consumer units or industrial distribution
systems according to DIN 43 880
- width 35 mm
- for connection of external residual current transformer,
e. g. DOLD ND 5016, ND5019

Download

Insulation monitor RN 5897/010

• Insulation monitoring according to IEC/EN 61557-8
• With connection facility of an external coupling device RP 5898
for voltages up to 1000 V
• Trigger output for insulation fault locating system
• 2 separate adjustable response thresholds
(using e.g. for pre-Alarm and Alarm)
• Setting range of 1st response value (Pre-Alarm): 20 kΩ … 2 MΩ
• Setting range of 2nd response value (Alarm): 1 kΩ … 250 kΩ
• 2 changeover contacts für insulation failures-Pre-Alarm and -Alarm
• Energized or de-energized on trip can be selected for indicator relay
• Display for indication of measured value, device parameters and
device status
• Setting the maximum leakage capacitance to shorten the response time
• Automatic and manual device self-test
• Alarm storage selectable
• Protection against manipulation by sealable transparent cover
• External control input for combined Test-/Reset-button
• 3 wide voltage input for auxiliary voltage
• Width 52.5 mm

Download

Radio controlled safety module UH 6900

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• Machine directive 2006/42/EG
• DIN EN 574: Safety of machinery - Two-hand control devices -
• DIN EN 300 220: Electromagnetic compatibility and Radio spectrum Matters
(ERM) - Short Range Devices (SRD) - Radio equipment to be used in
the 25 MHz to 1000 MHz frequency range with power levels ranging up
to 500 mW
• Depending on the operating mode, to connect:
- E-stop push-button (2-channel), safety gate, LC (non-contact safety
system, for example light curtain) of the type 4 in accordance with
EN 61 496 or the two-hand type IIIA in accordance with DIN EN 574.
- 1 start button
- Changeover switch (2-channel) to indicate radio use in the
Safety operation with optional radio control operating mode
• For two-way communication via radio:
- Safety shut-down commands
- Signals from 8 non-safety-relevant DC 24 V inputs at 8 non-safetyrelevant
DC 24 V semiconductor outputs
• Broken wire and short circuit monitoring function with error indication
• Semiconductor output to indicate poor or no radio control
• 2 semiconductor outputs for status indication
• LEDs to indicate
- status of module
- status of all inputs and outputs
- the radio transmission and its quality
• Width: 45 mm

Download

Insulation fault locator RR 5887

• Insulation troubleshooting in DC, AC and mixed IT systems in connection with the locating current injector RR 5886 according to DIN EN 61557-9 (VDE 0413-9):2009 and DIN EN 61557-1
(VDE 0413-1)
• Insulation coordination according to IEC 60664-1
• Connection of max. 4 or 8 differential current transformers depending on the design
• RS-485 bus connection to synchronise the test current output and optionally for the connection to the EDS measuring bus for reading insulation fault currents
• Status output of insulation fault detection via external switching output
• Memory characteristics adjustable via bridge Y1-Y2
• Collective signalling relay to output preliminary warning and alarm states
• Pushbutton for manual reset of alarm states as well as testing of differential current transformers and their calibration
• Terminal connection for the storage of alarm states
• Width: 105 mm

Download

Multifunction Measuring Relay MH 9300

• Multifunction measuring relay acc. to EN 60255-1
• Voltage monitoring (1- and 3-phase)
• Current monitoring
• Frequency monitoring
• Power factor cos phi
• Phase sequence, phase failure, asymmetry
• Effective-, reactive- and apparent power
• Start up delay, on delay
• Adjustable hysteresis 0.2 ... 50 % of response value
• Manual reset
• LCD for indication of the measuring values
• Relay output
MK 9300N: 1 changeover contact
MH 9300: 2 x 1 changeover contacts
• Relay function selectable (energized/de-energized on trip)
• As option with plugable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• MH 9300: Width 45 mm

Download

Insulation monitor RN 5897/300

• Insulation monitoring according to IEC/EN 61557-8
• 2 separate adjustable response thresholds
(using e.g. for pre-Alarm and Alarm)
• Setting range of 1st response value (Pre-Alarm): 20 kΩ … 1 MΩ:
• Setting range of 2nd response value (Alarm): 10 kΩ … 250 kΩ
• 2 changeover contacts für insulation failures-Pre-Alarm and -Alarm
• Energized or de-energized on trip can be selected for indicator relay
• LED for status indication
• Automatic and manual device self-test
• Alarm storage selectable
• Protection against manipulation by sealable transparent cover
• External control input for combined Test-/Reset-button
• 3 wide voltage input for auxiliary voltage
• Width 52.5 mm

Download

Residual current monitor, Type B RN 5883

• According to IEC/EN 62 020, VDE 0663
• For AC and DC systems Type B, according to IEC/TR 60755
• To detect earth faults in grounded voltage systems
• 4 setting ranges from 10 mA to 3 A
• Manual reset, with alarm and pre-warning
• With adjustable switching delay
• Energized or de-energized on trip
• LED indicator for operation, pre-alarm and alarm
• With test function
• LED-chain indicates fault current
• As option with analogue output
• Broken wire detection
• Protection against manipulation by sealable transparent cover
over setting switches
• Width: 52.5 mm

Download

Insulation monitor LK 5894

• Insulation monitoring according to IEC/EN 61557-8
• Detection of symmetric and asymmetric insulation faults
• 2 changeover contacts
• Prewarning threshold setting range: 20 kΩ ... 2 MΩ
• Alarm threshold setting range: 1 kΩ ... 250 kΩ
• Energized or de-energized on trip can be selected for output relay
• Setting the maximum leakage capacitance to shorten the response time
• Simple, clearly arranged adjustment of the device with screwdriver
• LED chain to indicate the current insulation resistance
• Display of active measuring circuits
• Automatic and manual device self-test
• Width: 90 mm

Download

Insulation monitor UH 5892

• Insulation monitoring according to IEC/EN 61557-8
• Detection of symmetric and asymmetric insulation faults
• 1 changeover contact for alarm
• Fixed response value RAN: 50 kΩ, other on request
• Internal reset and test pushbutton
• External test and reset pushbutton can be connected
• LED indicator for auxiliary voltage and alarm
• LED chain to indicate the current insulation resistance
• Automatic or manual reset, programmable
• Analogue output for insulating value
• External indicating instrument can be connected
• Closed circuit operation
• Open circuit operation on request
• With pluggable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• Width 45 mm