The present objectives of modern traffic management on road, rail and sea routes are safety, efficiency, and good environmental performance. The reliability of signaling systems, such as traffic lights or obstacle and landing markers and beacons, is also crucial. Reliable monitoring solutions are essential for the early recognition of errors and breakdowns. This way, dangerous situations can be avoided and a high level of traffic safety ensured.

Download

Insulation monitor RN 5897/010

• Insulation monitoring according to IEC/EN 61557-8
• With connection facility of an external coupling device RP 5898
for voltages up to 1000 V
• Trigger output for insulation fault locating system
• 2 separate adjustable response thresholds
(using e.g. for pre-Alarm and Alarm)
• Setting range of 1st response value (Pre-Alarm):...

Download

Radio controlled safety module UH 6900

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• Machine directive 2006/42/EG
• DIN EN 574: Safety of machinery - Two-hand control devices -
• DIN EN 300 220: Electromagnetic compatibility and...

Download

Locating current injector RR 5886

• Insulation troubleshooting in DC, AC and mixed IT systems in connection with the insulation fault locator RR 5887 according to DIN EN 61557-9 (VDE 0413-9):2009 and DIN EN 61557-1 (VDE 0413-1)
• Insulation coordination according to IEC 60664-1
• External control via insulation monitor possible
• Positive and negative test current...

Download

Insulation fault locator RR 5887

• Insulation troubleshooting in DC, AC and mixed IT systems in connection with the locating current injector RR 5886 according to DIN EN 61557-9 (VDE 0413-9):2009 and DIN EN 61557-1
(VDE 0413-1)
• Insulation coordination according to IEC 60664-1
• Connection of max. 4 or 8 differential current transformers depending on the design
•...

Download

Residual current monitor, Type B RN 5883

• According to IEC/EN 62 020, VDE 0663
• For AC and DC systems Type B, according to IEC/TR 60755
• To detect earth faults in grounded voltage systems
• 4 setting ranges from 10 mA to 3 A
• Manual reset, with alarm and pre-warning
• With adjustable switching delay
• Energized or de-energized on trip
• LED indicator...

Download

Insulation monitor LK 5894

• Insulation monitoring according to IEC/EN 61557-8
• Detection of symmetric and asymmetric insulation faults
• 2 changeover contacts
• Prewarning threshold setting range: 20 kΩ ... 2 MΩ
• Alarm threshold setting range: 1 kΩ ... 250 kΩ
• Energized or de-energized on trip can be selected for output...

Download

Insulation monitor UH 5892

• Insulation monitoring according to IEC/EN 61557-8
• Detection of symmetric and asymmetric insulation faults
• 1 changeover contact for alarm
• Fixed response value RAN: 50 kΩ, other on request
• Internal reset and test pushbutton
• External test and reset pushbutton can be connected
• LED indicator for auxiliary...