Solutions for the recycling industry

Recycling industry

The recycling industry produces secondary raw materials from waste. Jaw, impact and roll crushers are used to crush materials. The separation of waste for material recycling is performed by physical processes such as sieving, metal separation or the remelting of plastics. All these operations cause significant wear to the industrial equipment. Disturbances and irregularities can be detected and rectified with suitable monitoring solutions. The inclusion of an appropriate safety concept ensures improved safety for both humans and machinery.

Download

Phase Controller with analog control 4-20 mA; 0-10 V IN 9017

• Phase controller for resistive and motor load
• for permanent power up to 300 W
• Interference suppression limit value class B
• LED indication
• Devices available in 3 versions:
IN 9017/100: with current interface 4 ... 20 mA
and broken wire detection
IN 9017/200: with voltage interface 0 ... 10 V
IN 9017/211: with voltage interface 0 ... 10 V,
Umin adjustable, control input for
max. output current
• Width: 53 mm

Download

Intelligent motorstarter UG 9256

• According to IEC/EN 60 947-4-2
• To reverse 3 phase motors up to 550 W to 4 kW
• 2-phase softstart
• 4 potentiometer für setting of starting torque, deceleration torque ,
softstart /-stop, overcurrent limit or rated motor current
• 4 LEDs for status indication
• Reversing with relays without current, softstart, softstop with thyristor
• Galvanic separated 24V-inputs for clockwise- and anticlockwise
• Reset button on front
• Connection facility for external reset button
• Relay indicator output for operation
• Indicator output at customers specification (on request)
• Galvanic separation between control circuit and power circuit
• Galvanic separation between motor terminals and supply voltage
in the off or fault state
• Width: 22,5 mm

Download

Reversing Contactor BH 9253

• According to IEC/EN 60 947-1, IEC/EN 60 947-4-2
• Switching at zero-crossing
• To reverse 3 phase asynchronuos motors up to
5.5 kW / 400 V (7.5 HP / 460 V)
• Electrical interlocking of both directions
• Temperature monitoring to protect the power semiconductors
• Measured nominal current up to 20 A
• LEDs for status indication
• Galvanic separation between control circuit and power circuit
• 45 mm; 67.5 mm; 112.5 mm width

Download

Latching relay MK 8852

• According to IEC/EN 61 810-1
• Setting input A1 - A2
• Reset input A3 - A2
• Storage function
• Switch position indication
• Manual operation
• Width 22.5 mm

Download

Speed Controller SX 9240.01

• According to IEC/EN 60 947-1, IEC/EN 60 947-4-2
• For speed control of 3-phase asynchronous motors up to 5.5 kW
• Speed adjustment by potentiometer on the front
• Additional galvanic separated control input for external speed
control 0 ... 10 V
• Umin and Umax setting accessable behind screw cover
• Large motor voltage range
• Integrated temperature monitoring
• Fullfills the EMC requirement according to IEC/EN 61 000-6-4
limit class B, therefore screened wires are not necessary
between motor and controller
• 2 changeover monitoring contacts
• LED indicators for alarm and status
• Connection for thermistor to monitor temperature
• 100 mm and 122 mm width

Download

Latching relay AD 8851

• According to IEC/EN 61 810-1
• Manual operation possible
• Contact position indication via control lever
• max. 4 NC contacts, 4 NO contacts
• Width 45 mm

Download

Reversing Contactor With Current Monitor BH 9255

• According to IEC/EN 60 947-1, IEC/EN 60 947-4-2
• Switching at zero crossing
• To reverse 3 phase asynchronuos motors up to
5.5 kW / 400 V (7.5 HP / 460 V)
• Electrical interlocking of both directions
• Temperature monitoring to protect the power semiconductors
• Measured nominal current up to 20 A
• LEDs for status indication
• Galvanic separation between control circuit and power circuit
• With current monitor
• 45 mm; 67.5 mm; 112.5 mm width

Download

Speed Controller SX 9240.03

• According to IEC/EN 60 947-1, IEC/EN 60 947-4-2
• For speed control of 3-phase asynchronous motors up to 5.5 kW
• Speed adjustment by potentiometer on the front
• Additional galvanic separated control input for external speed
control 0 ... 10 V, 0 ... 20 mA, 4 ... 20 mA
• Umin and Umax setting accessable behind screw cover
• Large motor voltage range
• Integrated temperature monitoring
• Fullfills the EMC requirement according to IEC/EN 61 000-6-4
limit class B, therefore screened wires are not necessary
between motor and controller
• 2 changeover monitoring contacts
• LED indicators for alarm and status
• Connection for thermistor to monitor temperature
• 100 mm, 122 mm and 168 mm width

Download

Reversing Contactor With Softstart And Active Power Monitoring BI 9254

• According to IEC/EN 60 947-1, IEC/EN 60 947-4-2
• To reverse 3 phase motors
• Electrical interlocking of both directions
• 2-phase softstart
• Active power monitoring after softstart
• Temperature monitoring of power semiconductors
• LED indicator
• Internal auxiliary voltage are made from phase voltage
• Galvanic separation of control circuit and power circuit
• Space and cost saving with 3 functions in one compact unit
• Reducing of wiring and wiring failure
• Width 90 mm

Download

Residual current monitor, Type B RN 5883

• According to IEC/EN 62 020, VDE 0663
• For AC and DC systems Type B, according to IEC/TR 60755
• To detect earth faults in grounded voltage systems
• 4 setting ranges from 10 mA to 3 A
• Manual reset, with alarm and pre-warning
• With adjustable switching delay
• Energized or de-energized on trip
• LED indicator for operation, pre-alarm and alarm
• With test function
• LED-chain indicates fault current
• As option with analogue output
• Broken wire detection
• Protection against manipulation by sealable transparent cover
over setting switches
• Width: 52.5 mm

Download

Softstarter BA 9010

• Increases the life of squirrel cage motors and mechanical drives
• Easily fitted to existing installations
• 1 phase control
• For motors up to 5,5 kW (BA 9010) and to 11 kW (BN 9011)
• Semiconductors bridged after softstart
• Adjustable ramp time and starting torque
• LED indication
• DIN-rail mounting
• BA 9010: width 45 mm

Download

Softstarter BN 9011

• Increases the life of squirrel cage motors and mechanical drives
• Easily fitted to existing installations
• 1 phase control
• For motors up to 5,5 kW (BA 9010) and to 11 kW (BN 9011)
• Semiconductors bridged after softstart
• Adjustable ramp time and starting torque
• LED indication
• DIN-rail mounting
• BN 9011: width 100 mm

Download

Softstarter and softstop device GF 9016

• For soft and shockfree start of your asynchronous motors
• Less wearing and longer life for your motors and components
• Space saving and easy fitting
• Reduce load from supply mains by reducing of starting current
• According to IEC/EN 60 947-4-2
• Softstart with softstop
• For motors up to 37 kW
• 2-phase control
• Adjustable start up and deceleration time als well as
starting voltage, optionally with kickstart
• Without auxiliary voltage
• W3 connection is possible
• As option current control on softstart
• Up to 15 kW: width 45 mm
Up to 22 kW: width 52.5 mm

Your agents