Emergency stop module with time delay LG 5928 . Protection of people and machines . Emergency stop circuits on machines, Stop category 1 can be realised . Monitoring of safety gates Advantages . Compact, flexible and safe . Short response time . Ideal for designs according to the new safety standards Features . According to - Performance Level (PL) e and category 4 to EN ISO 13849-1 - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061 - Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511 . Output: 2 NO instantaneous contacts and 1 release delay contact . 1- or 2-channel connection . Line fault detection at the ON pushbuttons at connection on terminals S33-S34 . Manual restart with button on S33-S34 or automatic restart with bridge between S13-S34 . With or without cross fault monitoring in the E-stop loop . Indication for released time circuit . LED indication for supply, channel 1/2 and release delayed contacts . Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated), DIN 46228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46228-1/-2/-3 . As option with pluggable terminal blocks for easy exchange of devices - with screw terminals - or with cage clamp terminals . Width 22.5 mm Technical specifications Suited as safety gate monitor: Yes Cat. / PL acc. to EN ISO 13849-1: 4/e 1- / 2-channel: 1, 2 Connection: Screw terminals, Pluggable screw terminals, Pluggable cage clamp terminals Output contacts max.: 2 NO contacts, 1 NO contact delayed Width: 22,5mm Cross fault detection: Yes SIL CL acc. to IEC/EN 62061: 3 Approvals: UL Nominal voltage: DC Thermal current Ith max.: 8A Type: LG 5928 Manufacturer: E. Dold & Söhne GmbH & Co. KG Type: LG5928.41/61 DC24V 1-10S Art. No.: 0061683