Safety relays with forcibly guided contacts

Safety relays with forcibly guided contacts

Energy efficiency and safety for your applications

In the machine- and plantbuilding sector the safety becomes more and more important. Everywhere, safety modules and also safety control systems are used. Despite the increasing use of semiconductor relays, the electromechanical relays are still an important part. Safety relays, i.e. relays with mechanically forcibly guided contacts per DIN EN 61810-3, are used wherever people, machines and valuable goods must be protected from injury and damage. One such relay comprises at least one NC contact set and one NO contact set and is constructed such that the NC set and the NO set can never be closed at the same time. For example, if a NO contact fails when trying to open, the associated NC contact cannot close when the power supply is switched off.

Please select required language:

Flyer, Bistable relay OB 5623, File: pdf, File size 210 KB

Flyer, Safety relay OA 5623, File: pdf, File size 274 KB

Flyer, Safety relays OA 5642/43/44, File: pdf, File size 236 KB

Brochure, Catalog PCB relays, File: pdf, File size 7 MB

Brochure, Image brochure PCB relays, File: pdf, File size 1 MB

Choose a product:

Type of relay

Contact equipping

Contact material

Continuous current

Test voltage (AC) contact set - coil

Clearance and creepage distances, contact set - coil ≥

Type according to DIN EN 61810-3

Protection type

Approvals

For relay type

Download

Safety relays OA 5669

• According to DIN EN 61810-1, DIN EN 61810-3
• With forcibly guided contacts
• Clearance and creepage distances
contact-coil ≥ 8 mm,
contact - contact ≥ 5.5 mm
Double and reinforced insulation between contact sets
• Low rated power consumption
• High mechanical service life
• Compact size, small height
• Wash proof...

Download

Safety relays OA 5669/3___

• According to DIN EN 61810-1, DIN EN 61810-3
• With forcibly guided contacts
• Clearance and creepage distances:
contact - coil ≥ 8 mm,
contact - contact ≥ 5.5 mm
double and reinforced insulation between contact sets
• Low rated power consumption
• High mechanical service life
• For high ambient temperature up to +...

Download

Safety relays OA 5667

• According to DIN EN 61810-1, DIN EN 61810-3
• With forcibly guided contacts
• Clearance and creepage distances:
contact-coil ≥ 8 mm
version OA 5667.16 with double and reinforced insulation
• Low rated power consumption
• High mechanical service life
• Compact size, small height

Download

Safety relays, reinforc. insulation OA 5667/_____4

• According to DIN EN 61810-1, DIN EN 61810-3
• With forcibly guided contacts
• Clearance and creepage distances:
contact - coil ≥ 8 mm
contact - contact ≥ 5,5 mm
Double and reinforced insulation between contacts
• Low rated power consumption
• High voltage resistance ≥ 4 kV at contamination level 2
• High mechanical...

Download

Safety relays OA 5670

• According to DIN EN 61810-1, DIN EN 61810-3
• With forcibly guided contacts
• double and reinforced insulation between contact sets
acc. to EN 50178
• High dielectric strength
• High mechanical service life
• High switching reliability
• Compact size
• High thermal continuous current
• High voltage range
•...

Download

Safety relays OA 5611

• According to DIN EN 61810-1, DIN EN 61810-3
• With forcibly guided contacts
• High switching reliability due to crown contacts
• Low rated power consumption
• High mechanical service life
• High temperature range - 40 ... + 85°C
• High continiuous thermal current Ith = 8 A
• Compact size
• Optionally wash...

Download

Safety relays, sensitiv OA 5611/____S

• According to DIN EN 61810-1, DIN EN 61810-3
• With forcibly guided contacts
• High switching reliability due to crown contacts
• Very low rated power consumption
OA 5611: 0.36 W with 4 contacts
OA 5612: 0.5 W with 6 contacts
• High mechanical service life
• High temperature range - 40 ... + 85°C
• Compact size

Download

Safety relays, according DIN EN 50578 OA 5611/31__L1

• Acc. to DIN EN 61810-1, DIN EN 61810-3, DIN EN 50578 (UIC 736)
• With forcibly guided contacts
• High switching reliability due to crown contacts
• Low rated power consumption
• High mechanical service life
• High continiuous thermal current Ith = 8 A
• Compact size

Download

Safety relays OA 5612

• According to DIN EN 61810-1, DIN EN 61810-3
• With forcibly guided contacts
• High switching reliability due to crown contacts
• Low rated power consumption
• High mechanical service life
• High temperature range - 40 ... + 85°C
• High continiuous thermal current Ith = 8 A
• Compact size
• Optionally wash...

Download

Safety relays, sensitiv OA 5612/____S

• According to DIN EN 61810-1, DIN EN 61810-3
• With forcibly guided contacts
• High switching reliability due to crown contacts
• Very low rated power consumption
OA 5611: 0.36 W with 4 contacts
OA 5612: 0.5 W with 6 contacts
• High mechanical service life
• High temperature range - 40 ... + 85°C
• Compact size

Download

Safety relays OA 5621

• According to DIN EN 61810-1, DIN EN 61810-3
• With forcibly guided contacts
• Clearance and creepage distances:
contact - contact ≥ 5,5 mm
• Low rated power consumption and holding power
• High mechancial service life
• High temperature range
• High thermal continuous current
• 15,5 mm height
• Version with...

Download

Safety relays with double contacts OA 5621_D

• According to DIN EN 61810-1, DIN EN 61810-3
• With forcibly guided contacts
• High switching safety because of gold plated double contacts
• Clearance and creepage distances:
contact - contact ≥ 5,5 mm
• Low rated power consumption and holding power
• High mechancial service life
• High temperature range
• High...

Download

Safety relays OA 5622

• According to DIN EN 61810-1, DIN EN 61810-3
• With forcibly guided contacts
• Clearance and creepage distances:
contact - contact ≥ 5,5 mm
• Low rated power consumption and holding power
• High mechancial service life
• High temperature range
• High thermal continuous current
• 15,5 mm height
• Version with...

Download

Safety relays with double contacts OA 5622_D

• According to DIN EN 61810-1, DIN EN 61810-3
• With forcibly guided contacts
• High switching safety because of gold plated double contacts
• Clearance and creepage distances:
contact - contact ≥ 5,5 mm
• Low rated power consumption and holding power
• High mechancial service life
• High temperature range
• High...

Download

Safety relays OA 5623

• According to DIN EN 61810-1, DIN EN 61810-3
• With forcibly guided contacts
• Clearance and creepage distances:
contact - contact ≥ 5,5 mm
• Low rated power consumption and holding power
• High mechancial service life
• High temperature range
• High thermal continuous current
• Height: 15.8 mm

Download

Bistable relay OB 5623

• According to DIN EN 61810-1, DIN EN 61810-3
• With forcibly guided contacts
• Energy efficient; Low energy consumption, because of impulse control,
no holding consumption
• Bistable
Mechanical latching of contact position
• Safe separation between all current circuits
• Both coils non-polarised, neutral
• Defined...

Download

Safety relays OA 5601

• According to DIN EN 61810-1, DIN EN 61810-3
• With forcibly guided contacts
• High switching reliability due to crown contacts
• Clearance and creepage distances:
contact - coil ≥ 8 mm
contact - contact ≥ 5.5 mm
Double and reinforced insulation with pollution degree 2
Overvoltage category: III
• High voltage resistance ≥...

Download

Safety relays OA 5602

• According to DIN EN 61810-1, DIN EN 61810-3
• With forcibly guided contacts
• High switching reliability due to crown contacts
• Clearance and creepage distances:
contact - coil ≥ 8 mm
contact - contact ≥ 5.5 mm
Double and reinforced insulation with pollution degree 2
Overvoltage category: III
• High voltage resistance ≥...

Download

Safety relays OA 5603

• According to DIN EN 61810-1, DIN EN 61810-3
• With forcibly guided contacts
• High switching reliability due to crown contacts
• Clearance and creepage distances:
contact - coil ≥ 8 mm
contact - contact ≥ 5.5 mm
Double and reinforced insulation with pollution degree 2
Overvoltage category: III
• High voltage resistance ≥...

Download

Safety relays, according DIN EN 50578 OA 5603/39__L1

• Acc. to DIN EN 61810-1, DIN EN 61810-3, DIN EN 50578 (UIC 736)
• With forcibly guided contacts
• High switching reliability due to crown contacts
• Clearance and creepage distances:
contact - coil ≥ 8 mm
contact - contact ≥ 5.5 mm
Double and reinforced insulation with pollution degree 2
Overvoltage category: III
• High...

Download

Safety relays OA 5642

• According to DIN EN 61810-1, DIN EN 61810-3,
DIN EN 45545 (fire protection on railway vehicles)
• With forcibly guided contacts
• Safe separation betwenn coil/contact and contact/contact for
applications at pollution degree 2 with rated insulation voltage 250 V
• Clearance and creepage distances
contact - coil ≥ 5.5 mm
contact -...

Download

Safety relays OA 5643

• According to DIN EN 61810-1, DIN EN 61810-3,
DIN EN 45545 (fire protection on railway vehicles)
• With forcibly guided contacts
• Safe separation betwenn coil/contact and contact/contact for
applications at pollution degree 2 with rated insulation voltage 250 V
• Clearance and creepage distances
contact - coil ≥ 5.5 mm
contact -...

Download

Safety relays OA 5644

• According to DIN EN 61810-1, DIN EN 61810-3,
DIN EN 45545 (fire protection on railway vehicles)
• With forcibly guided contacts
• Safe separation betwenn coil/contact and contact/contact for
applications at pollution degree 2 with rated insulation voltage 250 V
• Clearance and creepage distances
contact - coil ≥ 5.5 mm
contact -...

Your contact


    Competence on site

    Damit wir für Sie Ihren persönlichen Ansprechpartner finden können, geben Sie bitte die fünfstellige Postleitzahl Ihres Ortes in das Suchfeld ein.

    Contact for: