Safety relays, reinforc. insulation OA 5667/_____4

OA5667.png

Features

• According to DIN EN 61810-1, DIN EN 61810-3
• With forcibly guided contacts
• Clearance and creepage distances:
contact - coil ≥ 8 mm
contact - contact ≥ 5,5 mm
Double and reinforced insulation between contacts
• Low rated power consumption
• High voltage resistance ≥ 4 kV at contamination level 2
• High mechanical service life
• Compact size, small height

• According to DIN EN 61810-1, DIN EN 61810-3
• With forcibly guided contacts
• Clearance and creepage distances:
contact - coil ≥ 8 mm
contact - contact ≥ 5,5 mm
Double and reinforced insulation between contacts
• Low rated power...

more...
Function Safety relays, reinforc. insulation
Type of relay monostabil
Contact equipping 2
Contact material AgSnO2; AgNi
Continuous current 6 A
Nominal voltage UN DC 6 - 110 V
Voltage Range UN 0,75 - 1,3 V
Test voltage (AC) contact set - coil ≥ 4 kV eff
Clearance and creepage distances, contact set - coil ≥ 8 mm
Temperature range (- / +) -40 - 85 °C
Type according to DIN EN 61810-3 A/B
Protection type RT II (flux-proof relay)
Approvals TÜV; cRUus
Size L x W x H 27 x 25 x 10,8 mm
Relay type OA 5667/_____4

Please select required language:

Datasheet / Operating Instructions, File: pdf, File size 179 KB