I/O Modules

Choose a product:

Number of inputs/outputs

Output: transistor / relay

Modbus RTU-interface

Enclosure design

Width

Thermal current Ith

Download

Input- / Outputmodule digital, for Modbus UG 9460

• According to IEC/EN 61 131-2
• Modbus RTU-interface
• 8 digital inputs for DC 24 V
• 4 Relay outputs ( 3 x 8 A, 1 x 16 A)
• LEDs for status indication
• 3 potentiometer for setting the modbus adress and baud rate
• 15 LEDs for status indication
• Width: 22.5 mm

Download

Input module, digital IP 5502

• According to IEC/EN 61 131-2, IEC/EN 50 178
• CANopen interface according to DS301 version 3.0 (Plug and Play
selectable), as option with galvanic separation
• 8 digital inputs for DC 24 V
• LED indicators for supply voltage and Bus status
• 70 mm width

Download

Input module, analog IL 5508

• According to IEC/EN 61 131-2
• CANopen interface according to DS301 version 3.0, DS401
• 2 analogue inputs with each 2 x 0 ... 10 V, 2 x 0 ... 20 mA
or 2 x Pt 100 (- 50 ... 300°C)
• Galvanic separation between inputs, bus and auxiliary supply
• LED indicators for supply voltage and Bus status
• 35 mm width

Download

Output module, digital IP 5503

• According to IEC/EN 61 131-2, IEC/EN 50 178
• CANopen interface according to DS301 version 3.0 (Plug and Play
selectable), as option with galvanic separation
• 8 relay outputs
• LED indicators for supply voltage, Bus status and state of contact
• 70 mm width

Download

Output module, analog IL 5507

• For installation in consumer units or industrial cabinets
• Space saving with 2 analogue outputs at 35 mm width
required space not more then for 2 standard line circuit breakers
• 2 analogue outputs, optionally with each 2 x 0 ... 10 V, 2 x 0 ... 20 mA,
2 x -10 V ... +10V oder 2 x 4 ... 20 mA
• 12 bit resolution allows accuracy of < ± 0.1 %
• Galvanic separation between logic, output and bus guarantees
high interference immunity
• No external voltage source necessary for output signal
• Can be used in all CANopen networks due to high data transmission
rate up to 1Mbit/s
• Free configuration software CoDeSys
• According to IEC/EN 61 131-2
• CANopen interface according to DS301 version 3.0, DS401
• LED indicators for supply voltage and Bus status

Download

I/O module, digital IN 5509

• According to IEC/EN 61 131-2
• CANopen interface according to DS 301 version 3.0, DS 401
• 4 digital inputs for DC 24 V
• 4 relay outputs
• LED indicators
• 52.5 mm width

Your agents


    Competence on site

    Damit wir für Sie Ihren persönlichen Ansprechpartner finden können, geben Sie bitte die fünfstellige Postleitzahl Ihres Ortes in das Suchfeld ein.

    Agents for: