Time switches

Time switches

Timer for saving energy and costs

With DOLD timers, you can save energy and costs by avoiding unnecessarily long activation times for lighting and other electricity consumers. The usage spectrum for timers is vast and ranges from stairwell and hallway lighting to courtyard lighting to follow-on controls for bathroom ventilation fans. Additional cost benefits from space savings result from the compact construction of the device. The continuous lighting function ensure that lighting is not interrupted during longer activities.

Choose a product:

Output contacts max.

Thermal current Ith

Resettable

Prewarning function before time expiry

Time extension by long push button operation

Cutoff-before-time capability

For flush-type boxes

Depth

Width

Download

Staircase Lighting Time Switch IK 8810

• According to EN 60669
• Setting range 0.5 ... 10 min.
• For 4-wire circuit L on push button and
3-wire circuit N on push button
• Can be retriggered
• Switch for continuous light on unit
• Contact: 16 A
• Width 17.5 mm

Download

Staircase Lighting Time Switch RK 8810/100

• According to EN 60 669
• Setting range 0.5 ... 10 min.
• For 4-wire circuit L on push button and
3-wire circuit N on push button
• Can be retriggered
• Switch for continuous light on unit
• Contact: 16 A
• Width 17.5 mm

Download

Staircase Lighting Time Switch IK8810/001

• According to EN 60669
• Setting range 0.5 ... 10 min.
• For 3-wire circuit N on push button
• Can be not retriggered
• Switch for continuous light on unit
• Contact: 16 A
• Width 17.5 mm

Download

Staircase Lighting Time Switch RK 8810/001

• According to EN 60669
• Setting range 0.5 ... 10 min.
• For 3-wire circuit N on push button
• Can not be retriggered
• Switch for continuous light on unit
• Contact: 16 A
• Width 17.5 mm

Download

Staircase Lighting Time Switch IK 8810/002

• According to EN 60669
• Setting range 0.5 ... 10 min.
• For 4-wire circuit L on push button and
3-wire circuit N on push button
• Can be retriggered
• with pre-warning shortly before end of time delay
• Switch for continuous light on unit
• Contact: 16 A
• Width 17.5 mm

Download

Time Switch With Pre-Warning RK 8810/002

• According to EN 60669
• Setting range 0.5 ... 10 min.
• For 4-wire circuit L on push button and
3-wire circuit N on push button
• Can be retriggered
• With pre-warning shortly before end of time delay
• Switch for continuous light on unit
• Contact: 16 A
• Width 17.5 mm

Download

Staircase Lighting Time Switch IK 8810/003

• According to EN 60669
• Setting range: short pressing of button 0.5 ... 10 min
long pressing of button 2 ... 40 min
• For 4-wire circuit L on push button and
3-wire circuit N on push button
• Can be retriggered
• with pre-warning shortly before end of time
• Switch for continuous light on unit
• Contact: 16 A
• Width 17.5 mm

Download

Lighting Time Switch RK 8810/003

• According to EN 60669
• Setting range: short pressing of button 0.5 ... 10 min
long pressing of button 2 ... 40 min
• For 4-wire circuit L on push button and
3-wire circuit N on push button
• Can be retriggered
• With pre-warning shortly before end of time delay
• Switch for continuous light on unit
• Contact: 16 A
• Width 17.5 mm

Download

Staircase Lighting Time Switch IK 8810/004

• According to EN 60669
• Setting range: for long times 3 ... 60 min
• For 4-wire circuit L on push button and
3-wire circuit N on push button
• With pre-warning shortly before end of time delay
• Light can be switched off before pre-warning
• Light can be retriggered after pre-warning
• Switch for continuous light on unit
• Contact: 16 A
• Width 17.5 mm

Download

Energy Saving Time Switch RK 8810/004

• According to EN 60 669
• Setting range: for long times 3 ... 60 min
• For 4-wire circuit L on push button and
3-wire circuit N on push button
• With pre-warning shortly before end of time delay
• Light can be switched off before pre-warning
• Light can be retriggered after pre-warning
• Switch for continuous light on unit
• Contact: 16 A
• Width 17.5 mm

Download

Fan Control Timer IK 8810/005

• According to EN 60669
• Setting range 0.5 ... 10 min
• After the light the fan switched on
• Switch for continuous light of the exhauster on unit
• Contact: 16 A
• Width 17.5 mm

Download

Fan Control Timer RK 8810/005

• According to DIN EN 61 095
• Setting range 0.5 ... 10 min
• After the light the fan switched on
• Switch for continuous light of the exhauster on unit
• Contact: 16 A
• Width 17.5 mm

Download

Energy Saving Time Switch RK 8810/006

• According to EN 60 669
• Setting range: for long times 3 ... 60 min
• For 4-wire circuit L on push button and
3-wire circuit N on push button
• Light can be switched off and retriggered
• Switch for continuous light on unit
• Contact: 16 A
• Width 17.5 mm

Download

Energy-Saving Switch IK 8813

• According to EN 60 669-1, EN 60 669-2-1
• Can be switched off before the time expires
• Operating times between 0.5 ... 60 min., as required
• IK 8813 with permanent light switch and LED indicator for contact
position
• IK 8813 for installation in rows, width 17.5 mm
• OA 8823 for installation in flush-mounted boxes

Download

Energy-Saving Switch OA 8823

• According to EN 60 669-1, EN 60 669-2-1
• Can be switched off before the time expires
• Operating times between 0.5 ... 60 min., as required
• IK 8813 with permanent light switch and LED indicator for contact
position
• IK 8813 for installation in rows, width 17.5 mm
• OA 8823 for installation in flush-mounted boxes

Download

Light timing switch IK 8814

• According to EN 60 669-1, EN 60 669-2-1
• Reswitching possible
• Operating times between 0.5 ... 60 min., as required
• IK 8814 with permanent light switch and LED indicator for contact
position
• IK 8814 for installation in rows, width 17.5 mm
OA 8824 for installation in flush-mounted boxes

Download

Light timing switch OA 8824

• According to EN 60 669-1, EN 60 669-2-1
• Reswitching possible
• Operating times between 0.5 ... 60 min., as required
• IK 8814 with permanent light switch and LED indicator for contact
position
• IK 8814 for installation in rows, width 17.5 mm
OA 8824 for installation in flush-mounted boxes

Download

Light timing switch IK 8825

• According to EN 60 669-1, EN 60 669-2-1
• With 2 delay times
- 0.3 ... 5 min. if the pushbutton is pressed briefly (< 1 s)
- 1.2 ... 20 min. if the pushbutton is pressed for a long time (> 1 s)
i.e. the delay time is four times as long
• Operating time adjustment with a screwdriver
• Reswitching possible
• IK 8825 with permanent light switch
• Permanent light as long as the pushbutton is pressed
• IK 8825 for installation on a top hat rail
• OA 8825 for installation in flush-mounted boxes
• Width IK 8825 17.5 mm

Download

Light timing switch OA 8825

• According to EN 60 669-1, EN 60 669-2-1
• With 2 delay times
- 0.3 ... 5 min. if the pushbutton is pressed briefly (< 1 s)
- 1.2 ... 20 min. if the pushbutton is pressed for a long time (> 1 s)
i.e. the delay time is four times as long
• Operating time adjustment with a screwdriver
• Reswitching possible
• IK 8825 with permanent light switch
• Permanent light as long as the pushbutton is pressed
• IK 8825 for installation on a top hat rail
• OA 8825 for installation in flush-mounted boxes
• Width IK 8825 17.5 mm

More information

Timers from DOLD are one of the most basic building automation devices and allow energy and cost savings by avoiding unnecessarily long activation times.

Your agents


    Competence on site

    Damit wir für Sie Ihren persönlichen Ansprechpartner finden können, geben Sie bitte die fünfstellige Postleitzahl Ihres Ortes in das Suchfeld ein.

    Agents for: