This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
"Allow all cookies" cookie
"Decline all cookies" cookie
CSRF token
Cookie preferences
Currency change
Customer recognition
Customer-specific caching
Individual prices
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Statistics & Tracking
Affiliate program
Google Tag Manager
Track device being used

Insulation monitor
AN 5873
- Article number: 0031599
- Variant: AN5873.11/101 UH AC230V 50K-OHM
The insulation monitor AN 5873 of the series VARIMETER IMD monitors the ground resistance of... more
Product description
The insulation monitor AN 5873 of the series VARIMETER IMD monitors the ground resistance of ungrounded DC and 3-phase AC voltage systems (IT-systems) with nominal voltage up to DC 0 ... 1000 V and 3 AC 24 ... 690 V. The unit detects symmetrical as well as unsymmetrical faults. The separate auxiliary supply allows also monitoring when the system is without voltage. To indicate the actual ground resistance value the unit has an LED chain and an analogue output. When a fault is detected the relay switches and the red LED lights up.
Technical specifications
Type: | AN 5873 |
Width: | 100 mm |
Response value: | 50 kΩ |
IMD type: | AC, DC, AC/DC |
Enclosure design: | Switch cabinet |
Earth fault indicator: | + |
With auxiliary voltage: | + |
Nominal voltage IT system: | 3AC 24 - 690, DC 0 - 1000 V |
Connection for indicator: | + |
Response value type: | Fest |
Downloads
Advantages
- Preventive fire and system protection
- Insulation monitoring of DC- and 3 AC-systems up to 1000 V
and 3 AC 690 V nominal voltage - No additional coupling device required
- Monitoring also with voltage-free mains
Features
- Insulation monitoring according to IEC/EN 61 557-8
- Fixed response value RAN
- Internal reset button
- External reset and test button can be connected
- LED indicator
- 1 changeover contact
- Programmable for manual reset or hysteresis function
- Analogue output for insulating value
- External connection of indicating instrument possible
- as option de-energized on trip or energized on trip
- Width 100 mm