RN 5884

Residual Current monitor, Type B

RN 5884

Contacts

Auxiliary voltage

Measuring range

Time delay

Variant

  • 0068738
  • RN5884.12 AC/DC80-240V 0-10S
The AC/DC sensitive residual current monitor RN 5884 from the VARIMETER RCM series allows an... more

Product description

The AC/DC sensitive residual current monitor RN 5884 from the VARIMETER RCM series allows an early detection of insulation faults and detects differential currents with AC as well as DC components in grounded voltage systems (type B). The measurement takes place via an external current transformer.

The residual current monitors can be easily parameterised and set via the operating buttons. If the measured differential current exceeds the set response values, this is signalled via the output relays K1 or K2. In order to detect faults in the system at an early stage, the residual current is shown visually on a display.

All versions have 2 output relays. Units for a connectable current transformer give an alarm at output relay K1 and a pre-alarm at output relay K2. Units for 2 current transformers output an alarm message separately for each measuring channel (CT1) at relay K1 or (CT2) at relay K2.

Other features include wire break detection, test function and adjustable switching delays. Thus, the residual current monitor RN 5884 provides an information head start for targeted and cost-effective maintenance measure before the system comes to a standstill.

Technical specifications

Width: 52,5 mm
Adjustable measuring ranges: 0,03 - 5 A
Operate delay: Yes
Classification: Type B (AC, DC even and pulsating)
Type of voltage: AC, DC
Broken conductor detection: Yes
Clear key: Yes
Test key: Yes
Relay contact / output: Yes
Enclosure design: Distribution board
Type: RN 5884

Advantages

  • Preventive fire and system protection
  • Increasing the availability of plants by early fault detection
  • Universal usage at AC/DC mains
  • Protection against manipulation by sealable transparent cover over setting switches

Features

  • According to IEC/EN 62020-1, VDE 0663
  • For AC and DC systems Type B
  • To detect earth faults in grounded voltage systems
  • Setting range from 30 mA ... 5 A
  • Manual / auto reset, with alarm and pre-warning
  • With adjustable switching delay
  • Energized or de-energized on trip
  • Set parameters directly on the device
  • Display
  • LED indicator for RUN- / SET- Mode; BUS, Error
  • With test function
  • As option with analogue output
  • As option with Modbus RTU-interface
  • Broken wire detection
  • Width 52.5 mm