Motor brake relay
BA 9034N/802
The supply voltage is connected to terminals L1-L2 and the interlock contact X5-X6 closes to enable the motor contactor. A green LED indicates operation. The motor can be started with the start button. The braking DC-voltage is generated on terminals T1 and T2. The braking sequence is as follows: When contact X3/X4 closes, the braking contactor is switched on after a safety time has elapsed for the duration of the braking time and the braking current flows through the stator winding. Opening contact X3/X4 ends the braking process. The maximum possible braking time is 31 s resp. 11 s.
| Braking current adjustable up to max.: | 32 A |
|---|---|
| Braking time adjustable up to max.: | 31 s |
| Signalling output: | Yes |
| Width: | 45 mm |
| Type: | BA 9034N/802 |
- Higher safety level and more economic by short stopping cycle
- Cost saving
- Compact design
- Easily appliance, no need for current measuring instrument
- Regulated braking current
- According to IEC/EN 60947-4-2
- For all single and 3-phase asynchronous motors
- DC-brake with one way rectification up to max. 32 Aeff
- Controlled by microcontroller
- Easily fitted to existing installations
- Wear free and maintenance free
- Integrated braking contactor
- DIN-rail mounting
- Adjustable braking current (controlled current)
- Width: 45 mm