Delay module, release delayed IL 7824

IL7824.png

Features

• According to
- Performance Level (PL) c and category 2 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL) 2 to IEC/EN 61508
- Category 2 to EN 954-1
• BA 7924.21/002 und BA 7924.21/003
- Performance Level (PL) d and category 3 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 nach IEC/EN 62061
- Safety Integrity Level (SIL) 2 to IEC/EN 61508
- Category 3 to EN 954-1
• Release delay
• Without auxiliary voltage
• Output: 1 NC, 1 NO contacts, forcibly guided
• Operating state display
• Optionally with adjustable or fixed time delay up to 30 s
• Optionally with redundant timing circuit
• Optionally with 1 or 2 separate timing circuits
• Optionally also in housing for distribution board
• Width 45 mm, 35 mm or 52.5 mm

• According to
- Performance Level (PL) c and category 2 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL) 2 to IEC/EN 61508
- Category 2 to EN 954-1
• BA 7924.21/002 und BA 7924.21/003
-...

more...
Function Delay module, release delayed
Cat. / PL according to EN ISO 13849-1 2/c
SIL CL according to IEC/EN 62061 2
1- / 2-channel 1
Output contacts max. 1 s; 1 ö
Thermal current Ith max. 8 A
Nominal voltage DC +
Time delay max. 3 sec
Connection S
Width 35 mm
Type IL 7824