Delay modules

Delay modules

Specific shut-down of drives

Delay modules from DOLD allow the specific shut-down of the drives which reduces the risk of injury. A typical area of use are high-speed tools that continue to move after shut-down. Productivity is not affected as the machine can be immediately started again. The emergency stop of the dangerous movement can be accelerated through a specific shut-down in accordance with stop category 1 by allowing motor braking functions to be applied during the switch-off delay and/or the speed of the drive can be regulated.

Choose a product:

Cat. / PL according to EN ISO 13849-1

SIL CL according to IEC/EN 62061

1- / 2-channel

Output contacts max.

Thermal current Ith max.

Nominal voltage DC

Nominal voltage AC

Nominal voltage AC/DC

Time delay max.

Approvals

Connection

Width

Download

Delay module, release delayed BG 7925

• According to
- Performance Level (PL) d and category 2 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL 2) to IEC/EN 61508
- Category 2 nach EN 954-1
• Variants /_ _2 to /_ _3
- Performance Level (PL) d and category 3 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
-...

Download

Delay module, release delayed BH 7925

• According to
- Performance Level (PL) d and category 2 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL 2) to IEC/EN 61508
- Category 2 nach EN 954-1
• Variants /_ _2 to /_ _3
- Performance Level (PL) d and category 3 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
-...

Download

Delay module, release delayed BG 7926

• According to
- Performance Level (PL) d and category 2 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL) 2 to IEC/EN 61508 and IEC/EN 61511
when connected to a suitable safety module
• Redundant and forcibly guided contacts
• 1 timing circuit
• Fixed time delay 1, 2 or 3 sec
•...

Download

Delay module, on delayed LG 7927

• According to
- Performance Level (PL) d and category 3 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL) 2 to IEC/EN 61508 and IEC/EN 61511
when connected to a suitable safety module
• Adjustable time delay
• As option fixed time delay
• High long life stability due to digital time base
•...

Download

Delay module, release delayed LG 7928

• According to
- Performance Level (PL) d and category 3 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL) 2 to IEC/EN 61508 and IEC/EN 61511
when connected to a suitable safety module
• Adjustable time delay
• As option fixed time delay
• High long life stability due to digital time base
•...

Download

Delay module, release delayed IL 7824

• According to
- Performance Level (PL) c and category 2 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL) 2 to IEC/EN 61508
- Category 2 to EN 954-1
• BA 7924.21/002 und BA 7924.21/003
- Performance Level (PL) d and category 3 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 nach IEC/EN...

Download

Delay module, release delayed IN 7824

• According to
- Performance Level (PL) c and category 2 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL) 2 to IEC/EN 61508
- Category 2 to EN 954-1
• BA 7924.21/002 und BA 7924.21/003
- Performance Level (PL) d and category 3 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 nach IEC/EN...

Download

Delay module, release delayed BA 7924

• According to
- Performance Level (PL) c and category 2 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL) 2 to IEC/EN 61508
- Category 2 to EN 954-1
• BA 7924.21/002 und BA 7924.21/003
- Performance Level (PL) d and category 3 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 nach IEC/EN...

More information

Delay modules from DOLD allow the specific shut-down of the drives which reduces the risk of injury.

Your contact


    Competence on site

    Damit wir für Sie Ihren persönlichen Ansprechpartner finden können, geben Sie bitte die fünfstellige Postleitzahl Ihres Ortes in das Suchfeld ein.

    Contact for: