Features

• According to
- Performance Level (PL) d and category 3 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL) 2 to IEC/EN 61508 and IEC/EN 61511
when connected to a suitable safety module
• Adjustable time delay
• As option fixed time delay
• High long life stability due to digital time base
• Adjustable with or without cross fault detection
• Output: 3 NO contacts + 1 NC contact + 1 forcibly guided
feedback contact
or 4 NO contacts + 1 forcibly guided feedback contact
• LED indicator for channel 1, 2 and operation voltage
• Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
• As option with pluggable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• Width 22.5 mm

• According to
- Performance Level (PL) d and category 3 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL) 2 to IEC/EN 61508 and IEC/EN 61511
when connected to a suitable safety module
• Adjustable...

more...

Advantages / Customer benefit

• Easy to realise safe timing circuits
• 4 forcibly guided output contacts at only 22.5 mm width

Function Delay module, on delayed
Cat. / PL according to EN ISO 13849-1 3/d
SIL CL according to IEC/EN 62061 2
1- / 2-channel 1
Output contacts max. 4 s; 1 ö
Thermal current Ith max. 5 A
Nominal voltage AC/DC +
Time delay max. 300 sec
Approvals UL
Connection S/PS/PC
Width 22,5 mm
Type LG 7927