Extension module
UG 6929
If more safety cicuits have to be switched, than a safety module provides, the extension module UG 6929 is used. It offers safe and reliable contact multiplication and re-enforcment for safety modules with monitoring of the feedback circuit. Safe semiconductor outputs can be extended by relay output contacts. The extension module has forcibly guided contacts and can be delivered with different contact arrangements.
| 1- / 2-channel: | 1, 2 |
|---|---|
| Approvals: | UL |
| Cat. / PL acc. to EN ISO 13849-1: | 4/e |
| Connection: | Pluggable cage clamp terminals, Pluggable cage clamp terminals 2-wire, Pluggable screw terminals |
| Nominal voltage: | AC, AC/DC |
| Output contacts max.: | 1 NC contact, 7 NO contacts |
| SIL CL acc. to IEC/EN 62061: | 3 |
| SIL nach IEC/EN 62061: | 3 |
| Thermal current Ith max.: | 8 A |
| Thermischer Strom Ith max.: | 8 |
| Type: | UG 6929 |
| Width: | 22,5 mm |
- Safety contact multiplication
- According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511 when connected to a suitable safety module - According to EN 50156-1 for furnaces
- Control with safety semiconductor outputs (light curtain, e-stop) possible
- Redundant and forcibly guided contacts
- Output: max.7 NO or 6 NO contacts / 1 NC contact, 1 NC contact for feedback circuit
- 1- or 2-channel
- Indication
- As option with pluggable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals - Width: 22.5 mm