Multifunction safety module
BH 5910
Protection of men and machines.
| 1- / 2-channel: | 1, 2 |
|---|---|
| Application: | Emergency stop, Light barrier, Safety gate, Two-hand |
| Approvals: | UL |
| Auxiliary contacts: | Yes |
| Cat. / PL acc. to EN ISO 13849-1: | 4/e |
| Connection: | Pluggable screw terminals |
| Cross fault detection: | Yes |
| Feedback for external monitoring: | Yes |
| Nominal voltage: | DC |
| SIL CL acc. to IEC/EN 62061: | 3 |
| SIL acc. to IEC/EN 62061: | 3 |
| Safe output contacts, redundant NO contacts: | 3 |
| Thermal current Ith max.: | 5 A |
| Thermal current Ith max.: | 5 |
| Type: | BH 5910 |
| Width: | 45 mm |
- According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508 - Functions selectable via rotational switches to connect max.:
- 8 E-stop circuits, single channel or
- 4 E-stop circuits, 2-channel or
- 4 light curtains or
- 2 light curtains and 1 E-stop circuit or
- 4 safety gates or
- 2 safety gates and 1 E-stop circuit or
- 4 pairs of 2-hand-buttons or Typ III A according to EN ISO 13851 or
- 2 pairs of 2-hand-buttons Typ III C according to EN ISO 13851 and 1 E-stop circuit - In addition selectable:
- Auto or manual reset (simulation input for gate monitor)
- Continuously monitored feedback circuit to monitor external contactors - Cross fault detection
- Short circuit and broken wire detection
- Outputs:
- 3 NO or 2 NO and 1 NC contacts
- 2 semiconductor outputs short circuit proof and overload protected - Under- and overvoltage detection and signalling
- LED indication for operation (RUN), channel 1/2
- 45 mm width