Multifunctional safety timer with instantaneous contacts
UG 6960
The multifunction safety timer UG 6960 provides protection of men and machines by enabling and disabling a safety circuit. This is done by the adjusted time delay function. Simply select 1 out of 5 delay functions with a rotary switch – ready. The adjusted time is safe over the complete setting range. The UG 6960 is available for different safety functions. It has safe delayed and instantaneous contacts.
| 1- / 2-channel: | 2 |
|---|---|
| Application: | Emergency stop, Light barrier, Safety gate, Safety mat, Two-hand |
| Approvals: | UL |
| Cat. / PL acc. to EN ISO 13849-1: | 4/e |
| Connection: | Pluggable cage clamp terminals, Pluggable cage clamp terminals 2-wire, Pluggable screw terminals |
| Cross fault detection: | Yes |
| Nominal voltage: | DC |
| SIL CL acc. to IEC/EN 62061: | 3 |
| SIL acc. to IEC/EN 62061: | 3 |
| Safe output contacts, redundant NO contacts: | 4 |
| Thermal current Ith max.: | 8 A |
| Thermal current Ith max.: | 8 |
| Type: | UG 6960 |
| Width: | 22,5 mm |
- Various delay functions adjustable at device:
- Release delay
- Release delay retriggerable
- On delay
- Fleeting on make / break
- Delay function settable via potentiometer - Various safety functions defined:
- E-Stop
- Safety gate
- Two-hand control
- Safety mat / Safety edge
- Exclusive or contacts
- Light curtain - Manual or auto start
- Instantaneous contact and safety delayed contacts
- Protection against manipulation by sealable transparent cover
- According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511 - Acc. to EN 50156-1 for furnaces
- Line fault detection on On-button:
- Manual restart or automatic restart
- With or without cross fault monitoring
- 2-channel
- Forcibly guided output contacts
- Output: 2 NO instantaneous contact and 2 NO contacts delayed
- 1 semiconductor output for instantaneous contacts
1 semiconductor output for delayed contacts - LED indicator for operation, safety function, time delay and failure
- As option with pluggable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals - Width: 22.5 mm