Product questions ?

+

Direct contact: 01245 324432

or send us a message.

Multifunctional safety module UG 6980

UG6980.png

Features

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• Acc. to EN 50156-1 for furnaces
• Line fault detection on On-button:
• Manual restart or automatic restart
• With or without cross fault monitoring
• 2-channel
• Forcibly guided output contacts
• Output: max. 4 NO instantaneous semiconductor monitoring output
• LED indicator for operation, delay contects and failure
• As option with pluggable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• Width: 22.5 mm

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• Acc. to EN 50156-1 for furnaces
• Line fault...

more...

Advantages / Customer benefit

• Adjustable safety functions:
- E-Stop
- Safety gate
- Two-hand control
- Safety mat / Safety edge
- Exclusive or contacts
- Light curtain
• Manual or auto start
• Only one device, different safety functions
• Protection against manipulation by sealable transparent cover

• Adjustable safety functions:
- E-Stop
- Safety gate
- Two-hand control
- Safety mat / Safety edge
- Exclusive or contacts
- Light curtain
• Manual or auto start
• Only one device, different safety functions
• Protection against...

more...
Function Multifunctional safety module
Application emergency stop +
Application light barrier +
Application safety gate +
Application two-hand +
Application safety mat +
Cat. / PL according to EN ISO 13849-1 4/e
SIL CL according to IEC/EN 62061 3
1- / 2-channel 2
Safe output contacts, redundant NO contacts max. 2
Thermal current Ith max. 8 A
Nominal voltage DC +
Cross fault detection +
Approvals UL
Connection PS/PC/PT
Width 22,5 mm
Type UG 6980

Please select required language:

Datasheet / Operating Instructions, File: pdf, File size 1 MB

EPLAN Electric P8 Makro, UG 6980, File: zip, File size 3 MB

The multifunctional safety module UG 6980 provides protection of men and machines by enabling and disabling a safety circuit. It is used together with e-stop buttons, safety gates, light curtains with self testing (type 4) to IEC/EN 61496-1, 2-hand buttons on presses for metal processing and productions machines with dangerous closing movements (type III C to EN 574) and safety mats, edges and tape switches. Simply select 1 out of 5 safety functions on rotary switches - ready. This reduces divers types of safety modules in stock and simplifies your disposition.

Accessory

 

 