Output module with output contacts
BG 5912
Realization of fail-safe control circuits for protection of people and machinery.
| Cat. / PL acc. to EN ISO 13849-1: | 4/e |
|---|---|
| SIL CL acc. to IEC/EN 62061: | 3 |
| SIL acc. to IEC/EN 62061: | 3 |
| Safe output contacts, redundant NO contacts: | 3, 4 |
| Safe output contacts, time delay: | 2, 3 |
| Width: | 22,5 mm |
| Type: | BG 5912 |
- According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508 - Safety outputs can be assigned to one or several function modules
(control unit or input modules). - Outputs:
- 4 NO contacts
- 3 NO contacts, 1 NC contact
- 3 NO contacts 0-3 s delay-release time-delay relay
- 2 NO contacts, 1 NC contact 0-3 s delay-release time-delay relay - Permanently monitored feedback loop for external contact reinforcement
- LEDs for status indication
- Width 22.5 mm