Input module with isolated inputs BH 5913.08/_0___

BH5913.png

Features

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• Input module for realization of
- 4 similar 2-channel inputs
- Emergency stop circuits
- Safety gate monitoring system
- Two-hand control type IIIA, IIIC acc. to DIN/EN 574
- Light curtain (LC type 4)
• The functions are selected via rotary switch
• 8 safety inputs
• 2 semiconductor outputs for status indication
• Broken wire and short circuit monitoring function with error indication
• LEDs for status indication
• Width
BG 5913.08/_0__: 22.5 mm
BH 5913.08/_0__: 45 mm

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• Input module for realization of
- 4 similar 2-channel inputs
-...

more...
Function Input module with isolated inputs
Application emergency stop +
Application light barrier +
Application safety gate +
Application two-hand +
Cat. / PL according to EN ISO 13849-1 4/e
Safety integrity level according to EN 574 lll A / lll C
Width 45 mm
Type BH 5913.08/_0___

Please select required language:

Datasheet / Operating Instructions, System overview SAFEMASTER M, File: pdf, File size 1 MB

Datasheet / Operating Instructions, File: pdf, File size 444 KB

Flyer, Software free safety system SAFEMASTER M, File: pdf, File size 343 KB

Brochure, System description SAFEMASTER M, File: pdf, File size 2 MB

 

 

Your contact


    Competence on site

    Damit wir für Sie Ihren persönlichen Ansprechpartner finden können, geben Sie bitte die fünfstellige Postleitzahl Ihres Ortes in das Suchfeld ein.

    Contact for: