Product questions ?

+

Direct contact: 01245 324432

or send us a message.

Emergency stop module BG 5925

BG5925.png

Features

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• Output: max. 3 NO contacts, see contacts
• Single and 2-channel operation
• Line fault detection on On-button
• Manual restart or automatic restart, switch S2
• With or without cross fault monitoring in the E-stop loop, switch S1
• LED indicator for channel 1 and 2 and Power
• Removable terminal strips
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 22.5 mm

 

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• Output: max. 3 NO contacts, see contacts
• Single and...

more...
Function Emergency stop module
Also suited as safety gate monitor +
Cat. / PL according to EN ISO 13849-1 4/e
SIL CL according to IEC/EN 62061 3
1- / 2-channel 1; 2
Output contacts max. 4 s
Thermal current Ith max. 5 A
Cross fault detection +
Nominal voltage DC +
Nominal voltage AC/DC +
Approvals UL
Connection PS
Width 22,5 mm
Type BG 5925

Please select required language:

Datasheet / Operating Instructions, File: pdf, File size 1 MB

 

 

Your contact


    Competence on site

    Damit wir für Sie Ihren persönlichen Ansprechpartner finden können, geben Sie bitte die fünfstellige Postleitzahl Ihres Ortes in das Suchfeld ein.

    Contact for: