Emergency stop module
BN 5930.48/203
Das BN 5930.48/203, BN 5930.48/204 dient dem sicherheitsgerichteten Unterbrechen eines Sicherheitsstromkreises. Es kann zum Schutz von Personen und Maschinen in Anwendungen mit Not-Halt-Tastern und Schutztüren verwendet werden.
| 1- / 2-channel: | 1, 2 |
|---|---|
| Cat. / PL acc. to EN ISO 13849-1: | 4/e |
| Connection: | Pluggable screw terminals |
| Cross fault detection: | Yes |
| Nominal voltage: | AC, DC |
| Output contacts max.: | 1 NC contact, 3 NO contacts |
| SIL CL acc. to IEC/EN 62061: | 3 |
| SIL acc. to IEC/EN 62061: | 3 |
| Suited as safety gate monitor: | Yes |
| Thermal current Ith max.: | 10 A |
| Thermal current Ith max.: | 10 |
| Type: | BN 5930.48/203 |
| Width: | 100 mm |
- Can be used for long leads in the e-stop loop. This allows a long distance between e-stop module and the e-stop button.
- Crossfault detection in the e-stop circuit
- According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 - BN 5930.48/203 with cross fault detection by connecting 2 different phases, max. 400 V,
BN 5930.48/204 with cross fault detection by connecting phase and neutral, max. 230 V - Dual voltage version
- Emergency-stop circuit T12, T22: optionally for AC 110 V / DC 60 V or AC 230 V / DC 110 V
- Output: 3 NO, 1 NC contacts for AC 400 V
- 1-channel or 2-channel circuit
- LED displays for channel 1, 2 and mains
- Feedback circuit X1 - X2 for monitoring external contactors
- Removable terminal strips
- Width 100 mm