Product questions ?

+

Direct contact: 01245 324432

or send us a message.

Safety module for elevator control LG 5925/034

LG5925_neu.png

Features

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
- Directive 2014/33/EU for elevators
• Output: 3 NO contacts, 1 NC contact
• Single or 2-channel operation
• Line fault detection on On-button
• Manual restart or automatic restart, switch S2
• With or without cross fault monitoring in the loop, switch S1
• LED indicator for state of operation
• LED indicator for channel 1 and 2
• Degree of protection IP40; can be mounted in cabinets and installations
with lower degree of protection without additional measures
(depending on ambient conditions)
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• As option with pluggable terminal blocks for easy exchange of devices
- with screw terminals
- or with cage clamp terminals
• Width 22.5 mm

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
- Directive 2014/33/EU for elevators
• Output: 3 NO contacts, 1 NC contact
•...

more...

Advantages / Customer benefit

• For elevators according to EN 81-20/-50

Function Safety module for elevator control
Cat. / PL according to EN ISO 13849-1 4/e
SIL CL according to IEC/EN 62061 3
1- / 2-channel 1; 2
Output contacts max. 3 s; 1 ö
Thermal current Ith max. 5 A
Cross fault detection +
Nominal voltage AC/DC +
Connection S/PS/PC
Width 22,5 mm
Type LG 5925/034

Please select required language:

Datasheet / Operating Instructions, File: pdf, File size 1 MB

Flyer, Solutions for elevator control systems, File: pdf, File size 1 MB

 

 

Your agents


    Competence on site

    Damit wir für Sie Ihren persönlichen Ansprechpartner finden können, geben Sie bitte die fünfstellige Postleitzahl Ihres Ortes in das Suchfeld ein.

    Agents for: