Light curtain controller with selectable operating modes
BH 5902
Protection of men and machines e.g. presses and conveyors
| 1- / 2-channel: | 1, 2 |
|---|---|
| Approvals: | TÜV, UL |
| Cat. / PL acc. to EN ISO 13849-1: | 4/e |
| Cross fault detection: | Yes |
| Nominal voltage: | DC |
| Output contacts max.: | 3 NO contacts |
| SIL CL acc. to IEC/EN 62061: | 3 |
| SIL acc. to IEC/EN 62061: | 3 |
| Thermal current Ith max.: | 5 A |
| Width: | 45 mm |
| Type: | BH 5902 |
- According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508 - To connect max.:
- 3 light curtains 2-channel or
- 2 light curtains 2-channel and 2 muting sensors 1-channel or
- 1 light curtain 2-channel and 4 muting sensors 1-channel or
- 2 light curtains 2-channel and key switch for stepping operation
- Additionally: Start button and machine contact with line fault detection - Broken wire detection on light curtain input
- Outputs:
- 3 NO or 2 NO and 1 NC
- 2 Semiconductor outputs, protected against short circuit and overload - Multifunction device, different functions selectable by rotational switches:
- Protective operation e.g. light curtains
- Protective operation with muting, e.g. conveyors
* Signal sequence of muting sensors can be selected
* Override function via start button
- Stepping operation e.g. on presses
* Optionally with key switch
* 1, 2 or 3 steps possible
* Setting of number of step possible via selector switch - Suitable to connect light curtains of type 4 or selftesting light curtains type 2 according to IEC/EN 61 496-1, crossfault monitoring in the light curtain
- With under- and overvoltage detection and indication
- Reaction time: max. 30 ms
- LED indication for RUN and Channel 1,2
- Width 45 mm