Emergency stop module BD 5935

BD5935.png

Features

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• 1- or 2-channel connection
• Operating state display
• LED display for channels 1 and 2
• Overvoltage and short circuit protection
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Output: optionally 1 NO / 1 NC or 3 NO / 1 NC contacts
• Optionally automatic ON function or activation via the ON pushbutton
• With fast auto start as option
• Width 45 mm

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• 1- or 2-channel connection
• Operating state display
•...

more...

Advantages / Customer benefit

• Safe disconnection of electrical circuits
• Line fault detection on ON pushbutton
• Gold plated contacts to switch low loads (signal to PLC)
• Optionally cross fault detection in emergency stop circuit
• Easy exchange of devices by removable terminal strips

• Safe disconnection of electrical circuits
• Line fault detection on ON pushbutton
• Gold plated contacts to switch low loads (signal to PLC)
• Optionally cross fault detection in emergency stop circuit
• Easy exchange of...

more...
Function Emergency stop module
Also suited as safety gate monitor +
Cat. / PL according to EN ISO 13849-1 4/e
SIL CL according to IEC/EN 62061 3
1- / 2-channel 1; 2
Output contacts max. 3 s; 1 ö
Thermal current Ith max. 10 A
Cross fault detection +
Nominal voltage DC +
Nominal voltage AC +
Approvals UL-Recognized
Connection PS
Width 45 mm
Type BD 5935

Please select required language:

Datasheet / Operating Instructions, File: pdf, File size 3 MB

EPLAN Electric P8 Makro, BD 5935, File: zip, File size 7 MB

The BD 5935 is used to interrupt a safety circuit in a safe way. It can be used to protect people and machines in applications with e-stop buttons and safety gates.

 

 