Emergency stop module BD 5987

BD5987.png

Features

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• Output: 2 NO contacts for AC 250 V
• 1-channel or 2-channel connection
• LED displays for channels 1 and 2
• Overvoltage and short circuit protection
• Wire connection: also 2 x 1,5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 45 mm


BD 5987._ _/001: same as BD 5987._ _ but
• Optionally automatic On function or after activation by the On pushbutton
• Optionally cross fault detection in emergency stop circuit


BD 5987.02/301: same as BD 5987.02/001 but
• Suitable also for elevators according to EN 81-20/-50
• Complies to the requirements of the directive 2014/33/EU for elevators
• According to
- Performance Level (PL) d and category 3 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL) 2 to IEC/EN 61508
• Shorter release time when opening the supply circuit
• Single-channel e-stop circuit

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• Output: 2 NO contacts for AC 250 V
• 1-channel or 2-channel...

more...

Advantages / Customer benefit

• Safe disconnection of electrical circuits
• Line fault detection at On pushbutton
• Gold-plated contacts to switch small loads (input for PLC)
• Optionally cross fault detection in emergency stop circuit

Function Emergency stop module
Also suited as safety gate monitor +
SIL CL according to IEC/EN 62061 3
1- / 2-channel 1; 2
Output contacts max. 2 s
Thermal current Ith max. 10 A
Cross fault detection +
Nominal voltage DC +
Nominal voltage AC +
Approvals UL-Recognized
Connection S
Width 45 mm
Type BD 5987

Please select required language:

Datasheet / Operating Instructions, File: pdf, File size 3 MB

The BD 5987 is used to interrupt a safety circuit in a safe way. It can be used to protect people and machines in applications with e-stop buttons and safety gates. The BD 5987.02/301 can be used as electronic replacement of a safety switch according to EN 81-1/-2, section 14.1.2.2.

 

 

Your contact


    Competence on site

    Damit wir für Sie Ihren persönlichen Ansprechpartner finden können, geben Sie bitte die fünfstellige Postleitzahl Ihres Ortes in das Suchfeld ein.

    Contact for: