Emergency stop module
BN 5930.48
The BN 5930.48 is used to interrupt a safety circuit in a safe way. It can be used to protect people and machines in applications with e-stop buttons and safety gates.
| 1- / 2-channel: | 1, 2 |
|---|---|
| Cat. / PL acc. to EN ISO 13849-1: | 4/e |
| Connection: | Pluggable screw terminals |
| Nominal voltage: | AC, DC |
| Output contacts max.: | 1 NC contact, 3 NO contacts |
| SIL CL acc. to IEC/EN 62061: | 3 |
| SIL acc. to IEC/EN 62061: | 3 |
| Thermal current Ith max.: | 5 A |
| Width: | 100 mm |
| Type: | BN 5930.48 |
- Same as BN 5983, but with other terminal designation (see circuit diagram)
- According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 - Output: 3 NO, 1 NC contacts for AC 400 V
- 1-channel or 2-channel circuit
- LED displays for channel 1, 2 and mains
- Feedback circuit X1 - X2 for monitoring external contactors
- Removable terminal strips
- Width 100 mm