• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• Output: 3 NO, 1 NC contacts for AC 400 V
• Optionally gold-plated contacts to switch small loads (input for PLC)
• 1-channel or 2-channel connection
• LED displays for channels 1 and 2
• Feedback circuit X3 - X4 for monitoring external contactors
• Removable terminal strips
• Overvoltage and short circuit protection
• Width 100 mm
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• Output: 3 NO, 1 NC contacts for AC 400 V
• Optionally...
Function | Emergency stop module |
Also suited as safety gate monitor | + |
Cat. / PL according to EN ISO 13849-1 | 4/e |
SIL CL according to IEC/EN 62061 | 3 |
1- / 2-channel | 1; 2 |
Output contacts max. | 3 s; 1 ö |
Thermal current Ith max. | 10 A |
Nominal voltage DC | + |
Nominal voltage AC | + |
Approvals | UL-Recognized |
Connection | PS |
Width | 100 mm |
Type | BN 5983 |
Please select required language:
Datasheet / Operating Instructions, File: pdf, File size 2 MB