Emergency stop module
BO 5988
- Protection of people and machines
- Emergency stop circuits on machines
- Monitoring of safety gates
| 1- / 2-channel: | 1, 2 |
|---|---|
| Approvals: | UL-Recognized |
| Cat. / PL acc. to EN ISO 13849-1: | 4/e |
| Connection: | Pluggable screw terminals |
| Cross fault detection: | Yes |
| Nominal voltage: | AC, DC |
| Output contacts max.: | 1 NC contact, 6 NO contacts |
| SIL CL acc. to IEC/EN 62061: | 3 |
| SIL acc. to IEC/EN 62061: | 3 |
| Thermal current Ith max.: | 10 A |
| Width: | 100 mm |
| Type: | BO 5988 |
- According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 - Output: max. 6 NO, 1 NC contacts or 1 NO contact for AC 250 V
- 1-channel or 2-channel connection
- Line fault detection at On pushbutton
- Feedback circuit X1-X2 for monitoring external contactors
- Integrated short-circuit and overvoltage protection
- LED displays for channels 1 and 2 and supply
- Removable terminal strips
- Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
- DIN 46 228-1/-2/-3-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
- Optionally with release delayed NO contact to 10 min
- Optionally automatic On function after connection of operating voltage
or activation via On pushbutton - Optionally cross fault detection in emergency stop control circuit
- Optionally dual voltage version
- Width 100 mm