Safety gate monitors

Safety gate monitors

Monitoring of movable safety door systems

DOLD offers you a wide spectrum of safety door monitoring modules for a wide variety of applications. The ready-to-connect switching devices mounted on DIN rails monitor the position of movable safety door devices. They can be used anywhere where entry and/or access to a room with dangerous movements makes protection necessary, e.g. for the operation of the machine, the configuration or troubleshooting. The safety door monitoring modules monitor the position of movable safety door switches that are actuated by the opening and/or closing of the safety device.

Please select required language:

Brochure, Catalog Safety devices, File: pdf, File size 15 MB

Choose a product:

Cat. / PL according to EN ISO 13849-1

SIL CL according to IEC/EN 62061

1- / 2-channel

Output contacts max.

Thermal current Ith max.

Cross fault detection

Nominal voltage DC

Nominal voltage AC

Connection

Width

Approvals

Also suited as safety gate monitor

Nominal voltage AC/DC

Download

Safety module for safety switches BG 5925/920

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• to connect:
- magnetic switch NE 5020
- magnetic switch NE 5021
• Output: max. 3 NO contacts, see contacts
• 2-channel operation
• Line fault detection on...

Download

Safety module for safety switches LG 5925/920

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• According to EN 50156-2 for furnaces
• to connect:
- safety switch NE 5020
- safety switch NE 5021
• Output: max. 4 NO contacts, see contacts
•...

Download

Emergency stop module BN 5930.48

• same as BN 5983, but with other terminal designation
(see circuit diagram)
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• Output: 3 NO, 1 NC contacts for AC 400 V
• 1-channel or 2-channel circuit
• LED...

Download

Emergency stop module BO 5988.47

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• Output: max. 6 NO, 1 NC contacts or 1 NO contact for AC 250 V
• 1-channel or 2-channel connection
• Line fault detection at On pushbutton
• Feedback...

Download

Emergency stop module BO 5988.61

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• Output: max. 6 NO, 1 NC contacts or 1 NO contact for AC 250 V
• 1-channel or 2-channel connection
• Line fault detection at On pushbutton
• Feedback...

Download

Emergency stop module UF 6925

• According to
-- Performance Level (PL) e and category 4 to EN ISO 13849-1
-- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
-- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• According to EN 50156-1 for furnaces
• 2-channel operation
• Forcibly guided output contacts
• With or without cross fault monitoring in...

Download

Emergency stop module LG 5925

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• According to EN 50156-2 for furnaces
• Output: max. 4 NO contacts, see contacts
• LG 5925.54: 1 semiconductor output
• Single and 2-channel...

Download

Emergency stop module BD 5935

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• 1- or 2-channel connection
• Operating state display
• LED display for channels 1 and 2
• Overvoltage and short circuit protection
• Wire connection:...

Download

Emergency stop module BD 5987

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• Output: 2 NO contacts for AC 250 V
• 1-channel or 2-channel connection
• LED displays for channels 1 and 2
• Overvoltage and short circuit protection
•...

Download

Emergency stop module with time delay BH 5928

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508 and IEC/EN 61511
• Output: 3 NO or 2 NO, 1 NC instantaneous contacts and
3 NO release delayed contacts
• Single and 2-channel operation
• Line fault detection on...

Download

Emergency stop module with time delay BI 5928

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508 and IEC/EN 61511
• Output: 3 NO or 2 NO, 1 NC instantaneous contacts and
3 NO release delayed contacts
• Single and 2-channel operation
• Line fault detection on...

Download

Emergency stop module BN 5930.48/203

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Category 4 to EN 954-1
• BN 5930.48/203 with cross fault detection by connecting
2 different phases, max. 400 V,
BN 5930.48/204 with cross fault detection by connecting
phase and neutral, max. 230 V
• Dual voltage...

Download

Emergency stop module BN 5930.48/204

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Category 4 to EN 954-1
• BN 5930.48/203 with cross fault detection by connecting
2 different phases, max. 400 V,
BN 5930.48/204 with cross fault detection by connecting
phase and neutral, max. 230 V
• Dual voltage...

Download

Emergency stop module BN 5983

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• Output: 3 NO, 1 NC contacts for AC 400 V
• Optionally gold-plated contacts to switch small loads (input for PLC)
• 1-channel or 2-channel connection
•...

More information

Safety door monitoring modules from DOLD are ready-for-connection switching devices that monitor the position of movable safety door systems.

Your contact


    Competence on site

    Damit wir für Sie Ihren persönlichen Ansprechpartner finden können, geben Sie bitte die fünfstellige Postleitzahl Ihres Ortes in das Suchfeld ein.

    Contact for: