Switch gear for safety switch LG 5925/920

LG5925_920.png

Features

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• According to EN 50156-2 for furnaces
• to connect:
- safety switch NE 5020
- safety switch NE 5021
• Output: max. 4 NO contacts, see contacts
• 1- or 2-channel operation
• Line fault detection on On-button
• Manual restart or automatic restart, switch S2
• with or without cross fault monitoring switch S1
• LED indicator for state of operation
• LED indicator for channel 1 and 2
• Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
• As option with plugable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• Width 22.5 mm

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• According to EN 50156-2 for furnaces
• to connect:
-...

more...
Function Switch gear for safety switch
SIL CL according to IEC/EN 62061 3
1- / 2-channel 1; 2
Output contacts max. 4 s
Thermal current Ith max. 8 A
Cross fault detection +
Nominal voltage DC +
Connection S/PS/PC
Width 22,5 mm
Type LG 5925/920

Please select required language: