Standstill / speed monitoring

Standstill / speed monitoring

SAFEMASTER S - Safe and comfortable standstill and speed monitoring

In accordance with the new machinery directive, the operating condition of a drive must be safely monitored and maintained during its shut-down. Typical applications are the release of locking mechanisms after the standstill of dangerous movements has been detected as well as work with open safety devices and reduced speed during calibration of the machine. The new speed monitors of the SAFEMASTER S series detect and signal the standstill and overspeed of machines and systems in automatic as well as set up operation. Its safely integrated safety door monitoring additionally provides a higher productivity and a higher degree of safety for the operating personnel.

Please select required language:

Flyer, Speed monitor UH 5947, File: pdf, File size 195 KB

Flyer, Speed monitor UH 6932, File: pdf, File size 167 KB

Flyer, Speed and frequency monitor UH 6937, File: pdf, File size 167 KB

Flyer, Standstill monitor LH 5946, File: pdf, File size 330 KB

Brochure, Catalog Safety devices, File: pdf, File size 15 MB

Choose a product:

Cat. / PL according to EN ISO 13849-1

SIL CL according to IEC/EN 62061

1- / 2-channel

Forcibly guided output contacts max.

Thermal current Ith max.

Nominal voltage DC

Nominal voltage AC

Nominal voltage AC/DC

Measuring-/ Motor Voltage max.

Approvals

Width

Indicator contacts

Connection

Download

Speed or stand-still monitor BH 5932

• According to
- Performance Level (PL) e and category 3 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• For stop category 0 according to EN 418
• 2-channel input
• To monitor rotation and linear movement
• PNP proximity sensor inputs
•...

Download

Stand-still monitor LH 5946

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL-Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508, IEC/EN 61511 and EN 61800-5-2
• Safe standstill detection on 3- and single-phase motors
• No external sensors necessary
• Independent of direction
• Broken wire...

Download

Speed monitor UH 5947

• According to
- Performance Level (PL) e und category 4 to EN ISO 13849-1: 2008
- SIL-Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• According to EN 60204
• Device setting on menu-driven display or via RJ45
(FCC Western-Modular 8P8C) with connection cable (copy function)
• Change tracking
•...

Download

Speed monitor UH 6932

• According to
- Performance Level (PL) e und category 4 to EN ISO 13849-1
- SIL-Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
- Safety Integrity Level (SIL) 3 to IEC/EN 61511
• Overspeed, underspeed or window monitoring
• Integrated user friendly frontside display
- Comfortable, menu guided...

Download

Speed and frequency monitor UH 6937

• According to
- Performance Level (PL) e und category 4 to EN ISO 13849-1
- SIL-Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
- Safety Integrity Level (SIL) 3 to IEC/EN 61511
• Over-, underfrequency or window monitoring of single or
3-phase in AC systems
• Integrated user friendly frontside...

More information

The standstill and speed monitors from DOLD distinguish themselves through the detect and signalling of standstill and overspeed of machines and systems.

Your contact


    Competence on site

    Damit wir für Sie Ihren persönlichen Ansprechpartner finden können, geben Sie bitte die fünfstellige Postleitzahl Ihres Ortes in das Suchfeld ein.

    Contact for: