Fleeting action relays / Pulse extender / Star-Delta timer

Fleeting action relays / Pulse extender / Star-Delta timer

Input and output wiping relays for time-dependent control systems

Machines and systems such as dosing systems and rinsing systems are where wiping relays are used. DOLD wiping relays are available as both input as well as output wiping relays. While the input wiping relays immediately switch the operating voltage to the work position after installation, output wiping relays are placed over the voltage control contact on the control input. If this is open, the relay immediately switches to the work position. Both relay types switch back to resting position immediately after the expiration of the set wiping time.

Choose a product:

Nominal voltage AC

Nominal voltage AC/DC

Nominal voltage DC

Output contacts

Enclosure design

Width

Approvals

Download

Fleeting action relay, fleeting on make BC 7931N

• According to IEC/EN 61 812-1
• Fleeting action
• Repeat time adjustable to 100 s
• Repeat accuracy ≤ 0.5 % + 10 ms
• Dual voltage supply
• LED indicator for contact position
• 1 changeover contact
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 22.5 mm

Download

Fleeting action relay, fleeting on make MK 9989

• According to IEC/EN 61 812-1
• Fleeting make
• Fleeting time up to 300 s or on request
• Repeat accuracy < ± 0,5 %
• Setting on absolute scale
• Available as 2-voltage version
• LED displays for availability and contact position
• 2 fleeting make or
1 fleeting make and 1 non-delayed changeover contact
• Also available with instantaneous contact
• Also available with CSA approval
• Width 22.5 mm

Download

Fleeting action relay, fleeting on make IK 7815

• According to IEC/EN 61 812-1
• Fleeting time up to 60 min.
• Adjustable fleeting time
• Repeat accuracy ≤ ± 1 %
• LED indicator for contact position
• 1 changeover contact
• Devices available in 2 enclosure versions:
IK 7815: depth 58 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 7815: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm

Download

Fleeting action relay, fleeting on make RK 7815

• According to IEC/EN 61 812-1
• RK 7813, RK 7815, RK 7816: Time ranges up to 10 h
• RK 7814: 4 time ranges up to 16 h
• LED indicator for state of contact
• Dual-voltage-version AC 230 V + AC/DC 24 V or
AC 110 ... 127 V + AC/DC 24 V
• 1 changeover contact
• As option units with second changeover contact
(only for voltage AC 230 V + AC/DC 24 )
- on delayed
- as instantaneous contact
• Start with impuls only for version RK 7816
• Start with space only for version RK 7816._ _ /_10
• As option with plug in terminal blocks for
exchange of devices, available
- with screw terminals
- with cage clamp terminals
• Width: 17.5 mm

Download

Fleeting action relay, fleeting on make SK 7815

• According to IEC/EN 61 812-1
• Fleeting time up to 60 min.
• Adjustable fleeting time
• Repeat accuracy ≤ ± 1 %
• LED indicator for contact position
• 1 changeover contact
• Devices available in 2 enclosure versions:
IK 7815: depth 58 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 7815: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
• Width 17.5 mm

Download

Fleeting action relay, fleeting on make, with manual mode IK 7826

• According to IEC/EN 61 812-1
• Fleeting action 0.05 ... 1 s, adjustable
• Fleet make contact
• Repeat accuracy ≤ 0.5 % + 10 ms
• Pushbutton for manual actuation of the contact
• 1 changeover contact for 16 A
• Width 17.5 mm

Download

Fleeting action relay, fleeting on make/- on break, - on make/break MK 9988

• According to IEC/EN 61 812-1
• Programmable: fleeting on make, fleeting on break,
fleeting on make and brake
• Fleeting time 0.3 ... 0.6 s fixed
• Repeat accuracy < ± 5 %
• LED indication for supply and contact position
• 2-wire-proximity sensor control
• Available with 1 or 2 changeover contacts
• Width 22.5 mm

Download

Pulse extender MK 7856/024

• According to IEC/EN 61 812-1
• Converts pulses to selectable length
• No repeat control during the time period (of the pulse)
• Pulse lengthening / shortening
• Time range up to 60 min
• Repeat accuracy ≤ ± 1 %
• Setting on aboslute scale
• 2-voltage version
• LED displays for availability and contact position
• Available with 1 or 2 changeover contacts
• Width 22.5 mm

Download

Star-Delta-Timer BC 7936N

• According to IEC/EN 61 812-1
• Time ranges up to 100 s
• Repeat accuracy ≤ 0.5 % + 10 ms
• 2-voltage design
• LED indicators for contact position
• 1 NO contact fleeting make
1 NO contact operate delayed
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 22.5 mm

Download

Star-Delta Timer MK 7853N

• According to IEC/EN 61 812-1
• Time delay up to 100 s
• Repeat accuracy < ± 0.5 %
• Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
• As option with pluggable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• Width 22.5 mm

More information

Wiping relays from DOLD are available as input as well as output wiping relays. After installation, the relays immediately switch the operating voltage on or off.

Your agents


    Competence on site

    Damit wir für Sie Ihren persönlichen Ansprechpartner finden können, geben Sie bitte die fünfstellige Postleitzahl Ihres Ortes in das Suchfeld ein.

    Agents for: