Timers on delayed

Timers on delayed

Time relays with contact delay for forward switching

With contact delayed time relays, the start is triggered by the activation of the operating voltage. The relay switches to the work position after the expiration of the configured delay time. Contact delayed time relays from DOLD are used for forward switching, e.g. pre-heating, or for delay times in switching systems such as for the delayed activation of system parts in burner controls, escalators and elevators.

Choose a product:

Nominal voltage AC

Nominal voltage AC/DC

Nominal voltage DC

Output contacts

Enclosure design

Width

Download

Timer, electronic MK 9906N

• According to IEC/EN 61 812-1
• 8 time ranges from 0.05 s to 300 h selectable via rotational switches
• Voltage range AC/DC 12 ... 240 V
• Adjustment aid for quick setting of long time values
• Suitable for 2-wire proximity sensor control
• 2 changeover contacts, one programmable as instantaneous contact
• LED indicators for operation, contact position and time delay
• Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
• As option connection of a remote potentiometer
• As option with time interruption / time adding input
• As option with pluggable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• 22.5 mm width

Download

Timer, electronic IK 9906

• According to IEC/EN 61 812-1
• 8 time ranges from 0.05 s to 300 h selectable via rotational switches
• Voltage range AC/DC 12 ... 240 V
• Adjustment aid for quick setting of long time values
• Suitable for 2-wire proximity sensor control
• 1 changeover contact
• As option connection of a remote potentiometer 10 kΩ
• As option with time interruption / time adding input
• LED indicators for operation, contact position and time delay
• Devices available in 2 enclosure versions:
I K 9906: depth 59 mm, with terminals at the bottom for installation
systems and industrial distribution systems according
to DIN 43 880
SK 9906: depth 98 mm, with terminals at the top for cabinets with
mounting plate and cable duct.
• 17.5 mm width

Download

Timer, electronic SK 9906

• According to IEC/EN 61 812-1
• 8 time ranges from 0.05 s to 300 h selectable via rotational switches
• Voltage range AC/DC 12 ... 240 V
• Adjustment aid for quick setting of long time values
• Suitable for 2-wire proximity sensor control
• 1 changeover contact
• As option connection of a remote potentiometer 10 kΩ
• As option with time interruption / time adding input
• LED indicators for operation, contact position and time delay
• Devices available in 2 enclosure versions:
I K 9906: depth 59 mm, with terminals at the bottom for installation
systems and industrial distribution systems according
to DIN 43 880
SK 9906: depth 98 mm, with terminals at the top for cabinets with
mounting plate and cable duct.
• 17.5 mm width

Download

Timer, electronic BC 7930N

• According to IEC/EN 61 812-1
• Time delay between 0.05 s ... 10 h
• Repeat accuracy ≤ 0.5 % + 10 ms
• Dual voltage supply
• LED indicator for contact position
• 1 changeover contact
• Wire connection: also 2 x 1.5 mm2 stranded ferruled
(isolated), DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 22.5 mm

Download

Timer, electronic BC 7934N

• According to IEC/EN 61 812-1
• 8 switching ranges from 0.05 s ... 16 h
• Infinite variable delay on every range 1 : 10
• Dual-voltage design as standard (e.g. AC 230 V + AC/DC 24 V)
• LED indicator for contact position
• 1 changeover contact
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 22.5 mm

Download

Timer, electronic MK 7858

• According to IEC/EN 61 812-1
• Delay of 0.25 ... 640 s or min.
• 4 switchable time ranges
• Repeat accuracy ≤ ± 0.5 %
• Can be controlled with 2-wire initiators at terminals A1-A2,
residual current ≤ 5 mA
• Available as 2-voltage version
• Available with instantaneous contact
• 2 changeover contacts
• 2 LED displays for power supply and contact position
• Width 22.5 mm

Download

Timer, electronic IK 7813

• According to IEC/EN 61 812-1
• 1 changeover contact
• Delay up to 60 min.
• Repeat accuracy ≤ 1 %
• LED indicator for contact position
• Devices available in 2 enclosure versions:
IK 7813: depth 58 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 7813: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable ducts
• Width 17.5 mm

Download

Timer, electronic RK 7813

• According to IEC/EN 61 812-1
• RK 7813, RK 7815, RK 7816: Time ranges up to 10 h
• RK 7814: 4 time ranges up to 16 h
• LED indicator for state of contact
• Dual-voltage-version AC 230 V + AC/DC 24 V or
AC 110 ... 127 V + AC/DC 24 V
• 1 changeover contact
• As option units with second changeover contact
(only for voltage AC 230 V + AC/DC 24 )
- on delayed
- as instantaneous contact
• Start with impuls only for version RK 7816
• Start with space only for version RK 7816._ _ /_10
• As option with plug in terminal blocks for
exchange of devices, available
- with screw terminals
- with cage clamp terminals
• Width: 17.5 mm

Download

Timer, electronic SK 7813

• According to IEC/EN 61 812-1
• 1 changeover contact
• Delay up to 60 min.
• Repeat accuracy ≤ 1 %
• LED indicator for contact position
• Devices available in 2 enclosure versions:
IK 7813: depth 58 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 7813: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable ducts
• Width 17.5 mm

Download

Timer, electronic IK 7814

• According to IEC/EN 61 812-1
• 4 time ranges up to 640 min.
• Repeat accuracy ≤ 1 %
• LED indicator for contact position
• 1 changeover contact
• Devices available in 2 enclosure versions:
IK 7814: depth 58 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 7814: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable ducts
• Width 17.5 mm

Download

Timer, electronic RK 7814

• According to IEC/EN 61 812-1
• RK 7813, RK 7815, RK 7816: Time ranges up to 10 h
• RK 7814: 4 time ranges up to 16 h
• LED indicator for state of contact
• Dual-voltage-version AC 230 V + AC/DC 24 V or
AC 110 ... 127 V + AC/DC 24 V
• 1 changeover contact
• As option units with second changeover contact
(only for voltage AC 230 V + AC/DC 24 )
- on delayed
- as instantaneous contact
• Start with impuls only for version RK 7816
• Start with space only for version RK 7816._ _ /_10
• As option with plug in terminal blocks for
exchange of devices, available
- with screw terminals
- with cage clamp terminals
• Width: 17.5 mm

Download

Timer, electronic SK 7814

• According to IEC/EN 61 812-1
• 4 time ranges up to 640 min.
• Repeat accuracy ≤ 1 %
• LED indicator for contact position
• 1 changeover contact
• Devices available in 2 enclosure versions:
IK 7814: depth 58 mm, with terminals at the bottom for
installation systems and industrial distribution
systems according to DIN 43 880
SK 7814: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable ducts
• Width 17.5 mm

Download

Timer, electronic IK 7825

• According to IEC/EN 61 812-1
• Delay of 0.05 s ... 60 min.
• Repeat accuracy ≤ 0.5 % + 10 ms
• Pushbutton for manual actuation of the contact
• 1 or 2 changeover contacts for 16 A
• Width 17.5 mm

Download

Timer, electronic IK 8808

• For two-wire technology
• According to IEC/EN 61 812-1
• programmable time ranges between 0.06 ... 160 s or 0.06 ... 160 min
• Programmable nominal voltage AC/DC 24 ... 240 V
• Repeat accuracy ≤ ± 1 %
• Thyristor output for 10 ... 800 mA
• Width 17.5 mm

Download

Timer, electromechanical with elapsed-time indication AA 7616

• According to IEC/EN 61 812-1
• Delay up to 60 h
• 6 switchable time ranges, adjustable on front side
• Repeat accuracy ≤ ± 0.5 % (≤ ± 1 % for ranges 3 s and 6 s)
• Time lapse display
• Switching position display (except for EH 7616)
• With instantaneous contact
• Available no-voltage safe
• EF 7616: front side, protected against beam water, IP 65
• AA 7616: width 45 mm
EC 7616: front surface 48 x 72 mm
EF 7616: front surface 2 x 72 mm
EH 7616: front surface 96 x 96 mm

Download

Timer, electromechanical with elapsed-time indication EC 7616

• According to IEC/EN 61 812-1
• Delay up to 60 h
• 6 switchable time ranges, adjustable on front side
• Repeat accuracy ≤ ± 0.5 % (≤ ± 1 % for ranges 3 s and 6 s)
• Time lapse display
• Switching position display (except for EH 7616)
• With instantaneous contact
• Available no-voltage safe
• EF 7616: front side, protected against beam water, IP 65
• AA 7616: width 45 mm
EC 7616: front surface 48 x 72 mm
EF 7616: front surface 2 x 72 mm
EH 7616: front surface 96 x 96 mm

Download

Timer, electromechanical with elapsed-time indication EF 7616

• According to IEC/EN 61 812-1
• Delay up to 60 h
• 6 switchable time ranges, adjustable on front side
• Repeat accuracy ≤ ± 0.5 % (≤ ± 1 % for ranges 3 s and 6 s)
• Time lapse display
• Switching position display (except for EH 7616)
• With instantaneous contact
• Available no-voltage safe
• EF 7616: front side, protected against beam water, IP 65
• AA 7616: width 45 mm
EC 7616: front surface 48 x 72 mm
EF 7616: front surface 2 x 72 mm
EH 7616: front surface 96 x 96 mm

Download

Timer, electromechanical with elapsed-time indication EH 7616

• According to IEC/EN 61 812-1
• Delay up to 60 h
• 6 switchable time ranges, adjustable on front side
• Repeat accuracy ≤ ± 0.5 % (≤ ± 1 % for ranges 3 s and 6 s)
• Time lapse display
• Switching position display (except for EH 7616)
• With instantaneous contact
• Available no-voltage safe
• EF 7616: front side, protected against beam water, IP 65
• AA 7616: width 45 mm
EC 7616: front surface 48 x 72 mm
EF 7616: front surface 2 x 72 mm
EH 7616: front surface 96 x 96 mm

Download

Timer, electromechanical with elapsed-time indication AA 7610

• According to IEC/EN 61 812-1
• Delay up to 60 h
• Repeat accuracy ≤ ± 0.5 %
(≤ ± 1 % at range 6 s)
• Time display
• Delayed and instantaneous contact
• As option no-voltage safe version
• AA 7610: 45 mm
EC 7610: front surface 48 x 72 mm
EF 7610: front surface 72 x 72 mm
EH 7610: front surface 96 x 96 mm

Download

Timer, electromechanical with elapsed-time indication EC 7610

• According to IEC/EN 61 812-1
• Delay up to 60 h
• Repeat accuracy ≤ ± 0.5 %
(≤ ± 1 % at range 6 s)
• Time display
• Delayed and instantaneous contact
• As option no-voltage safe version
• AA 7610: 45 mm
EC 7610: front surface 48 x 72 mm
EF 7610: front surface 72 x 72 mm
EH 7610: front surface 96 x 96 mm

Download

Timer, electromechanical with elapsed-time indication EF 7610

• According to IEC/EN 61 812-1
• Delay up to 60 h
• Repeat accuracy ≤ ± 0.5 %
(≤ ± 1 % at range 6 s)
• Time display
• Delayed and instantaneous contact
• As option no-voltage safe version
• AA 7610: 45 mm
EC 7610: front surface 48 x 72 mm
EF 7610: front surface 72 x 72 mm
EH 7610: front surface 96 x 96 mm

Download

Timer, electromechanical with elapsed-time indication EH 7610

• According to IEC/EN 61 812-1
• Delay up to 60 h
• Repeat accuracy ≤ ± 0.5 %
(≤ ± 1 % at range 6 s)
• Time display
• Delayed and instantaneous contact
• As option no-voltage safe version
• AA 7610: 45 mm
EC 7610: front surface 48 x 72 mm
EF 7610: front surface 72 x 72 mm
EH 7610: front surface 96 x 96 mm

Download

Timer, digital EC 7801

• According to IEC/EN 61 812-1
• For delay up to 9999 min.
• Repeat accuracy < ± 1 %
• LED indicators for power supply and state of contact
• 1 changeover contact
• As option with second C/O as instantaneous contact
• As option 2, 3 or 4 decades
• 48 x 72 mm front surface

Download

Timer, digital EC 9621

• According to IEC/EN 61 812-1
• For delay up to 99.99 h
• Repeat accuracy < ± 0.5 %
• LED indicators for power supply and state of contact
• As option with time progression indication
• As option 1 or 2 changeover contacts or semiconductor outputs
• 48 x 72 mm front surface

Download

Timer, electropneumatic AA 7512

• According to IEC/EN 61 812-1
• Delay up to 180 s
• Repeat accuracy < ± 5 %
• 1 changeover contact delayed, 1 changeover contact without delay
• Width 45 mm

More information

Contact delayed time relays from DOLD for forward switching or delay times in switching systems, e.g. delayed activation of system parts.