Cookie preferences
This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
"Allow all cookies" cookie
"Decline all cookies" cookie
CSRF token
Cookie preferences
Currency change
Customer recognition
Customer-specific caching
Individual prices
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Show the facebook fanpage in the right blod sidebar
Statistics & Tracking
Affiliate program
Google Tag Manager
Track device being used
Delay module, release delayed
BG 7926
- Article number: 0050806
- Type: BG7926.54 AC/DC24V TV=3S
The delay module BG 7926 is used for delayed stopp of a movement or to control the stop of parts... more
Product description
The delay module BG 7926 is used for delayed stopp of a movement or to control the stop of parts of machines.
Technical specifications
Width: | 22,5 mm |
Cat. / PL acc. to EN ISO 13849-1: | 2/d |
SIL CL acc. to IEC/EN 62061: | 2 |
Nominal voltage: | AC/DC |
Thermal current Ith max.: | 5 A |
1- / 2-channel: | 1 |
Time delay max.: | 3 s |
Approvals: | UL-Recognized |
Connection: | Pluggable screw terminals |
Output contacts max.: | 1 NC contact, 5 NO contacts |
Type: | BG 7926 |
Advantages
- Easy to realise safe timing circuits
- 5 forcibly guided output contacts at only 22.5 mm width
Features
- Can be used in conjunction with a suitable switchgear / control unit in safety applications as follows:
- Up to PL d and category 2 according to EN ISO 13849-1
- Up to SIL 2 according to EN 61508 and EN 61511 - Redundant and forcibly guided contacts
- 1 timing circuit
- Fixed time delay 1, 2 or 3 sec
- Without auxiliary supply
- Output: 5 NO contacts or 4 NO contacts / 1 NC contact, 1 NC contact for feed back circuit
- Indicator LED for operation
- Removable terminal strips
- Wiring diameter: Also 2 x 1.5 mm2 stranded ferruled with sleeve DIN 46228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46228-1/-2/-3
- Width 22.5 mm