Measuring and monitoring limit values for electrical variables

Systems and equipment are becoming more and more complex, due to growing automation, rationalisation, and the increasing use of control electronics in machines. Required maintenance work is increasing, making it more difficult for humans to modify such systems. Not only the security, but also the service lives of such systems are highly important. Preventative maintenance which helps avoid malfunctions or reliably correct them in a short time helps to save costs. Using measurement and monitoring relays is becoming more and more economical, as lost production time is difficult to make up.

You’ve faced the situation before: complex production systems, high demands for quality, delivery time, and delivery reliability, with permanent cost pressure. Today more than ever, these kinds of pressures require comprehensive operational readiness to maintain and even improve international competitiveness. In practice, however, comprehensive operational readiness is often difficult to achieve; ageing, moisture, contamination, mechanical damage, and other factors can lead to creeping insulation failures. Such undiscovered issues can lead to cost-intensive system and operational standstills, repair costs, and typically high follow-up costs due to production shutdowns. In the worst case scenario, insulation failures can even be a frequent cause of fires and personal injuries.

Product Finder

Filter

Insulation monitor IL 5880
  • Auxiliary voltage: AC , DC
  • IMD type: AC
  • Nominal voltage IT system: AC 0 - 500 V
  • Response value: 5 - 500 kΩ
  • Width: 35 mm
Insulation monitor IL 5881
  • Auxiliary voltage: DC
  • IMD type: DC
  • Nominal voltage IT system: DC 12 - 280 V , DC 24 - 500 V
  • Response value: 5 - 500 kΩ
  • Width: 35 mm
Insulation monitor LK 5894
  • Approvals: UL
  • Auxiliary voltage: DC
  • IMD type: AC , AC/DC , DC
  • Nominal voltage IT system: AC 0 - 690 V , DC 0 - 690 V
  • Response value: 1 - 250 kΩ
  • Width: 90 mm
Insulation monitor LK 5895
  • Approvals: UL
  • Auxiliary voltage: DC
  • Classification: For photovoltaic systems
  • IMD type: AC , AC/DC , DC
  • Nominal voltage IT system: AC 0 - 1000 V , DC 0 - 1000 V
  • Response value: 1 - 250 kΩ
  • Width: 90 mm
Insulation monitor LK 5896
  • Approvals: UL
  • Auxiliary voltage: DC
  • Classification: For photovoltaic systems
  • IMD type: AC , AC/DC , DC
  • Nominal voltage IT system: AC 0 - 1000 V , DC 0 - 1000 V
  • Response value: 1 - 250 kΩ
  • Width: 90 mm
Multifunction measuring relay MH 9300
  • 1- / 3-phase: 1 , 3
  • Auxiliary voltage: AC , AC/DC , DC
  • Measuring range max.: 690 V
  • Operate delay: Yes
  • Standard measuring range: 3 AC 24 - 400 V
  • Width: 45 mm
Multifunction relay, digital MK 7830N
  • Nominal voltage: AC , AC/DC
  • Time function(s): Cyclic timer , Fleeting on break , Fleeting on make , Fleeting on make and brake , Impulsgeber , Off-delay, with control signal , On- and Off-delay , On-delay , Pulse extender
  • Time range: 0,02 s - 9999 h
  • Width: 22,5 mm
Cyclic timer MK 7854N
  • Approvals: UL
  • Connection facility for remote potentiometer: Yes
  • Nominal voltage: AC/DC
  • Time function(s): Cyclic timer
  • Time range: 0,05 s - 300 h
  • Width: 22,5 mm
Multifunction measuring relay MK 9300N
  • 1- / 3-phase: 1 , 3
  • Auxiliary voltage: DC
  • Measuring range max.: 400 V
  • Operate delay: Yes
  • Standard measuring range: 3 AC 24 - 400 V
  • Width: 22,5 mm
Fuse Monitor RL 9075
  • 1- / 3-phase: 1 , 3
  • Approvals: UL
  • Measuring range max.: 3 AC 110 V
  • Standard measuring range: 3 AC 110 V / 64 V
  • Width: 35 mm
Voltage Relay RL 9836
  • 1- / 3-phase: 1
  • Auxiliary voltage: Without
  • Nominal voltage max.: DC 250 V
  • Operate delay: Yes
  • Width: 35 mm
Current Relay RL 9853
  • 1- / 3-phase: 1
  • Auxiliary voltage: AC , DC
  • Measuring range: AC/DC 0,002 - 10 A
  • Operate delay: Yes
  • Width: 35 mm
Voltage Relay RL 9854
  • 1- / 3-phase: 1
  • Auxiliary voltage: Without
  • Nominal voltage max.: AC 300 V
  • Operate delay: Yes
  • Width: 35 mm
Phase monitor RL 9877
  • 1- / 3-phase: 1 , 3
  • Approvals: UL
  • Auxiliary voltage: Without
  • Measuring range max.: 230 V
  • Standard measuring range: 3/N AC 80 - 230 V / 45 - 130 V
  • Width: 35 mm
Residual current monitor, Type B RN 5883
  • Adjustable measuring ranges: 0,01 - 3 A
  • Approvals: UL
  • Classification: Type B (AC, DC even and pulsating)
  • Operate delay: Yes
  • Width: 52,5 mm
Insulation monitor RN 5897
  • Approvals: UL
  • Auxiliary voltage: AC/DC , DC
  • Classification: For mobile power generators
  • IMD type: AC , AC/DC , DC
  • Nominal voltage IT system: AC 0 - 230 V , DC 0 - 230 V
  • Response value: 1 - 100 kΩ
  • Width: 52,5 mm
Insulation monitor RN 5897/010
  • Approvals: DNV , UL
  • Auxiliary voltage: AC/DC , DC
  • IMD type: AC , AC/DC , DC
  • Nominal voltage IT system: AC 0 - 230 V , AC 0 - 1000 (Coupling device) V , DC 0 - 230 V , DC 0 - 1500 (Coupling device) V
  • Response value: 1 - 250 kΩ
  • Width: 52,5 mm
Insulation monitor RN 5897/011
  • Approvals: DNV , UL
  • Auxiliary voltage: AC/DC
  • Bus interface: Modbus RTU
  • IMD type: AC , AC/DC , DC
  • Nominal voltage IT system: AC 0 - 230 V , AC 0 - 1000 (Coupling device) V , DC 0 - 230 V , DC 0 - 1500 (Coupling device) V
  • Response value: 1 - 2000 kΩ
  • Width: 52,5 mm
Insulation monitor RN 5897/300
  • Approvals: UL
  • Auxiliary voltage: AC/DC , DC
  • Classification: For mobile power generators
  • IMD type: AC , AC/DC , DC
  • Nominal voltage IT system: AC 0 - 230 V , DC 0 - 230 V
  • Response value: 10 - 250 kΩ
  • Width: 52,5 mm
Insulation monitor RN 5897/320
  • Approvals: UL
  • Auxiliary voltage: AC/DC , DC
  • Classification: For DC charging stations
  • IMD type: AC , AC/DC , DC
  • Nominal voltage IT system: AC 0 - 690 (Coupling device) V , DC 0 - 1000 (Coupling device) V
  • Response value: 1 - 100 kΩ
  • Width: 52,5 mm
Phase monitor RN 9877
  • 1- / 3-phase: 1 , 3
  • Approvals: UL
  • Auxiliary voltage: Without
  • Measuring range max.: 525 V
  • Standard measuring range: 3/N AC 175 - 525 V / 100 - 300 V
  • Width: 52,5 mm
Locating current injector RR 5886
  • Auxiliary voltage: AC/DC 24 - 80 V , AC/DC 85 - 230 V
  • Bus interface: Modbus RTU , RS-485
  • Nominal voltage IT system: DC, AC, 3AC 24 - 455 V
  • Operating mode: Master / Slave
  • Width: 105 mm
Insulation fault locator RR 5887
  • Auxiliary voltage: AC/DC 24 - 80 V , AC/DC 85 - 230 V
  • Bus interface: Modbus RTU , RS-485
  • Nominal voltage IT system: DC, AC, 3AC 24 - 455 V
  • Operating mode: Slave
  • Width: 105 mm
Multifunction measuring relay, for Modbus UG 9400
  • 1- / 3-phase: 1 , 3
  • Auxiliary voltage: AC , AC/DC
  • Bus interface: Modbus RTU
  • Measuring range max.: 690 V
  • Operate delay: Yes
  • Standard measuring range: 3 AC 24 - 690 V
  • Width: 22,5 mm
Insulation monitor UH 5892
  • Auxiliary voltage: AC/DC
  • IMD type: AC , AC/DC , DC
  • Nominal voltage IT system: AC 0 - 400 V , DC 0 - 600 V
  • Response value: 50 kΩ
  • Width: 45 mm