Software free safety system

Software free safety system

SAFEMASTER M - Decentralised, modular, freely configurable!

The modular safety system SAFEMASTER M is an optimal solution for many areas of machinery and system construction. The safety functions can be adjusted the respective requirements cost-effectively with software-free device configuration. SAFEMASTER M essentially consists of four modules: the control unit as well as the input, output and diagnosis module. The input module with freely selectable safety functions can be assigned to various output modules. The optional field bus connection allows the visualisation of the system status. The result is increased system availability.

Please select required language:

Datasheet / Operating Instructions, System overview SAFEMASTER M, File: pdf, File size 1 MB

Flyer, Software free safety system SAFEMASTER M, File: pdf, File size 343 KB

Brochure, System description SAFEMASTER M, File: pdf, File size 2 MB

Catalogue, Safety technique, File: pdf, File size 15 MB

Choose a product:

Application emergency stop

Application light barrier

Application safety gate

Application two-hand

Application start

Application stop

Cat. / PL according to EN ISO 13849-1

Safe output contacts, redundant NO contacts

Safe output contacts, time delay

Auxiliary contacts

Feedback for external monitoring

Width

Safety integrity level according to EN 574

Download

Control Unit BH 5911.03

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• For emergency stop function, the following inputs
and outputs are available:
Inputs: 4 monitored start inputs, or
3 start inputs and 1 stop input and
2 Emergency stop...

Download

Control Unit BH 5911.22

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• For emergency stop function, the following inputs
and outputs are available:
Inputs: 4 monitored start inputs, or
3 start inputs and 1 stop input and
2 Emergency stop...

Download

Input module BG 5913.08/_0___

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• Input module for realization of
- 4 similar 2-channel inputs
- Emergency stop circuits
- Safety gate monitoring system
- Two-hand control type IIIA, IIIC acc. to DIN/EN...

Download

Input module with isolated inputs BH 5913.08/_0___

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• Input module for realization of
- 4 similar 2-channel inputs
- Emergency stop circuits
- Safety gate monitoring system
- Two-hand control type IIIA, IIIC acc. to DIN/EN...

Download

Input module BG 5913.08/_1___

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
· Input module for realization of
- 4 mixed 2-channel inputs
- Emergency stop circuits
- Safety gate monitoring system
- Two-hand control type IIIA, IIIC acc. to DIN/EN...

Download

Input module BG 5913.08/_2___

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
· Input module for combination of 4 of the following functions to be set
via rotary switch:
- safety gate monitoring function (2 x 2 changeover contacts)
- Light...

Download

Input module BG 5913.08/_3___

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• Input module mit einer per Stufenschalter einstellbarer
Combination of the following 3 functions:
- Light curtains (LC) type 4 with manual or automatic start
- E-stop...

Download

Input module BG 5914.08/_0___

• According to
- Performance Level (PL) d and category 2 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL 2) to IEC/EN 61508
• Input module for realization of:
- 8 E-STOP, single-channel, autostart
- 6 E-STOP, single-channel, + 1 E-STOP, 2-channel, autostart
- 5 E-STOP, single-channel, + 1...

Download

Input module with isolated inputs BH 5914.08/_0___

• According to
- Performance Level (PL) d and category 2 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL 2) to IEC/EN 61508
• Input module for realization of:
- 8 E-STOP, single-channel, autostart
- 6 E-STOP, single-channel, + 1 E-STOP, 2-channel, autostart
- 5 E-STOP, single-channel, + 1...

Download

Input module with monitoring function BG 5915.08/_1___

• According to
- Performance Level (PL) d and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• Input module with enabling inputs
• for connection of 2 channel
- safety gates
- e-stop buttons
- light curtain (LC) Type 4
- change over switch
- enabling swtich
•...

Download

Output module BG 5912.04

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• Safety outputs can be assigned to one or several function modules
(control unit or input modules).
• Outputs:
- 4 NO contacts
- 3 NO contacts, 1 NC contact
- 3 NO...

Download

Output module BG 5912.48

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• Safety outputs can be assigned to one or several function modules
(control unit or input modules).
• Outputs:
- 4 NO contacts
- 3 NO contacts, 1 NC contact
- 3 NO...

Download

Output module BG 5912.86

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• Safety outputs can be assigned to one or several function modules
(control unit or input modules).
• Outputs:
- 4 NO contacts
- 3 NO contacts, 1 NC contact
- 3 NO...

Download

Output module BG 5912.95

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• Safety outputs can be assigned to one or several function modules
(control unit or input modules).
• Outputs:
- 4 NO contacts
- 3 NO contacts, 1 NC contact
- 3 NO...

Download

Diagnostic Module for CANopen BG 5551

• For transmitting the status information from the control unit and the input
modules, e.g. input and error states, start button and safety output
assignments, to a control system or bus-capable display
• Galvanic separation
• Adjustment of transmission via rotary switch
• LED indicators for operating voltage and status
• Width...

Download

Diagnostic Module for Profibus DP BH 5552

• For transmitting the status information from the control unit and the input
modules, e.g. input and error states, start button and safety output
assignments, to a control system or bus-capable display
• Electrical isolation
• Automatic recognition of transmission speed
• LED indicators for operating voltage and status
• Width...

More information

The modular, software-free safety system SAFEMASTER M offers the optimal solution for many areas of machinery and system construction.

Your contact


    Competence on site

    Damit wir für Sie Ihren persönlichen Ansprechpartner finden können, geben Sie bitte die fünfstellige Postleitzahl Ihres Ortes in das Suchfeld ein.

    Contact for: