Cookie preferences
This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
"Allow all cookies" cookie
"Decline all cookies" cookie
CSRF token
Cookie preferences
Currency change
Customer recognition
Customer-specific caching
Individual prices
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Show the facebook fanpage in the right blod sidebar
Statistics & Tracking
Affiliate program
Google Tag Manager
Track device being used
Valve monitoring module
BH 5904
- Article number: 0059391
- Type: BH5904.02/00MF2/61 DC24V
Protection of people and machines. The module BH 5904 monitors the positions of valve lifter in... more
Product description
Protection of people and machines. The module BH 5904 monitors the positions of valve lifter in standard hydraulic blocks for presses.
Technical specifications
Width: | 45 mm |
Nominal voltage: | DC |
Cat. / PL acc. to EN ISO 13849-1: | 4/e |
Approvals: | UL |
Type: | BH 5904 |
Features
- According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508 - Way of valve monitoring adjustable (2 NC, 2NO, 1 changeover contact)
- Reset button to acknowledge after fault detection
- Available with continuous monitoring of the valve or just with one check per cycle
- Contact reinforcement by external contactors possible
- Short circuit and cross fault detection
- Broken wire detection
- Outputs: 2 NO contacts
- 2 semiconductor outputs with short circuit, overload and temperature protection to monitor the status
- Under and overvoltage detection
- Reaction time: max. 28 ms
- LED operation indicators (run1, run2 )
- Width 45 mm