Card relay (plug-in/print relay)

Card relays, also called plug-in/print relays, are used for galvanic isolation of circuits as well as for signal matching and signal amplification. The horizontal and vertical versions allow optimal adaptation to their application.

Category (C)

Classification of the safety-related parts of a control system with regard to their resistance (K, B, 1, 2, 3, and 4) to faults and their behaviour in the event of a fault, which is achieved on the basis of the structural arrangement of the parts and/or their reliability. [DIN EN 954-1, see also DIN EN ISO 13849-1]

Cleaning / Washing

In accordance with the protection class for wash-tight relays, RT III, the relays can be washed in a suitable cleaning medium. For environmental reasons, we recommend not cleaning the assemblies. Should cleaning be necessary for certain reasons, the following procedural criteria must be observed:Cool down the assembly as previously described.The temperature of the washing medium should not exceed 55 °C and the washing time should be as short as possible (e.g. 2 min).Do not use ultrasonic cleaning to avoid possible contact adhesion.Do not use cleaning additives. If a detergent is used, make sure that it does not damage the relay or the seal.Avoid high-pressure cleaning

Clock generator

Function as with the flasher relay, except that the pulse time and pause time are different and can therefore be set separately.

Closed-circuit current principle

With the closed-circuit current principle, the contact falls back into the rest position as soon as the response condition is fulfilled.

Coating, painting or potting

For some applications, printed circuit boards must be painted or encapsulated. Only relays with protection class RT III should be used for this purpose. We recommend one-component lacquers based on epoxy or polyurethane resins applied by spraying. Silicones or materials containing silicone must not be used. Special suitability tests of the paint must be carried out. Due to capillary action, the lacquers can creep between the relay and the PCB. During the subsequent drying or curing process, they may not cure completely there. Lacquer vapours may then penetrate into the interior of the relay and impair its functionality. If the PCB is encapsulated with the relays, heat dissipation may be altered by the encapsulation. The user must carry out additional tests to check whether the performance data of the relays may have to be reduced.

Command device

The command device expands the key transfer system with variable command, signalling, dialling and emergency stop functions. The system thus becomes a "control centre" from which, among other things, command functions can be controlled. The module can be installed with the key transfer system and thus enables direct command execution at access points of machines and systems.

Common cause of failure (CCF)

Failures of different units due to a single event, whereby the failures are not based on mutualcause.

Consent switch

The enabling switch must be operated manually so that the protective effect of the guards can be cancelled. It alone must not be used to initiate hazardous conditions. A "second, conscious" command is required for this.

Contact lifetime

Electrical service life indicating the expected number of switching cycles at a defined load, e.g. AC 15.

Continuous current

This is the current that a relay contact may carry continuously without exceeding the permissible temperature rise in relation to the defined ambient conditions.

Control cabinet housing

Modern electronics require innovative enclosure solutions. The enclosures are available in all common widths from 6.2 to 200 mm with a choice of screw or spring-loaded terminals for installation in control cabinets.The enclosure system, which is available in many colours, offers a wide range of applications and designs. In addition, it is characterised by an unmistakable design and maximum functionality. The universal enclosure system includes all standard widths available on the market, from the 6.2 mm narrow compact solution to the 90 mm wide large-capacity enclosure. Special widths are also possible. The connection technology is extremely variable and freely selectable. This means that the signal density or the number of poles can be conveniently varied according to requirements. On three terminal levels, up to 30 connections are possible with a width of 22.5 mm.The modular enclosures are also available with a sealable, transparent front cover. This reliably protects memory cards, sockets and setting elements from manipulation and accidental misadjustment.

Control category (CC)

Classification of the safety-related parts of a control system with regard to their resistance (SK B, 1, 2, 3, and 4) to faults and their behaviour in the event of a fault, which is achieved on the basis of the structural arrangement of the parts and/or their reliability [EN 954-1].

Cooling of wash-tight relays

After wave soldering, the assembly must be cooled down as gently and stress-free as possible to the desired low and constant temperature in a cold air flow before the washing process. If a washing process follows, this temperature must be matched as closely as possible to the temperature level of the washing medium. The optimum cooling gradient for this must be determined individually for the relay or the assembly under original process conditions. The recommended cooling gradient is in the range of 0.5 K / s to 2.5 K / s. As part of the qualification of the assembly, the optimum cooling process must be determined and used as a basis for processing. This avoids possible damage, such as micro-cracks on the relays (and also other, neighbouring components). Too rapid cooling or sudden temperature changes, which could have an effect on the assembly as a cold shock, must not take place.

Coupling modules

Coupling modules are designed with positively driven contacts according to IEC 61810-3. The positively driven NC contacts enable monitoring of the NO contacts. As links between logic and load, they serve to switch safety-related functions

Coupling relay

Electronic controls have long been an integral part of modern automation technology. As early as the beginning of the 1970s, they gradually replaced the contactor and relay controls that had been common until then. This reduced the power consumption of the controls, which work with extra-low voltages, to a minimum. However, the energy requirements of the power level for driving motors, magnetic couplings or hydraulic cylinders have not changed until today. They still require a correspondingly high amount of electrical energy.Coupling relays therefore take over the necessary adaptation of logic and power level. They also ensure safe isolation. This makes coupling relays the ideal links between the highly sensitive, almost powerless logic level of a PLC, control system or process computer and the rough operation on the machine.

Creepage distance

Is the shortest distance along the surface of an insulating material between two conductive parts.

Cross-circuit detection

Ability of a SAG to cross-connect immediately or within the scope of cyclical monitoring, after detection of the fault, to assume the agreed safe state.

Cross-connection

Electrically conductive connection / short circuit between the input channels of an emergency stop module. A cross-circuit can only occur with multi-channel unit control.

Current monitoring

To ensure blocking protection, the motor current in T3 is monitored. The switching threshold is adjustable via potentiometer. This provides permanent protection of the motor and machine against overload.

Current relay

Current relays monitor AC and DC currents for exceeding or falling below a set threshold. Depending on the current relay, one or more consumers can be checked with one device. Current relays are used, among other things, in stone and woodworking machines and wherever it is necessary to monitor voltages.

Cyclic test

Before or at the next request of the safety function, an error is automatically detected, i.e. at the latest at each switch-on cycle of the evaluation unit.