I

11 Posts in this encyclopedia category

Impulse generator

The input pulse is converted into an output pulse with a defined length (set time).

Impulse shaper

When the operating voltage is applied, the relay changes to the working position for the set time. Further activations are only evaluated after the set time has elapsed.

In-Rail Bus (In-Rail)

The BUS system is the most elegant solution for the safe and fast transmission of signals, data and energy. In modular applications, it replaces complex individual wiring for connecting, distributing and supplying. In this way, this DIN rail bus reduces the wiring effort and the susceptibility to errors. It thus ensures more economic efficiency, higher flexibility and also makes subsequent system adaptations child's play.The IN-RAIL-BUS system is based on a carrier profile. This can be easily integrated into the 35 mm standard mounting rail and accommodates the customisable BUS circuit board. With its high flexibility, this concept enables many customised solutions.

Indicator current path

A signalling current path is used to generate a non-safety-related output signal.

Initial fault occurrence time (EEZ)

Time span in which the probability of the occurrence of a safety-critical initial fault is sufficiently low for the requirement class under consideration. The time span begins with the last time at which the system under consideration was in a state assumed to be fault-free for the requirements class under consideration. Error-controlling measures are not taken into account.

Insulation fault location

See insulation fault location system, insulation monitors.

Insulation fault location system

In weitläufigen Industrieanlagen kann die Fehlerlokalisierung von Isolationsfehlern zu einem kosten- und zeitaufwendigen Prozess werden. Das Isolationsfehlersuchsystem lokalisiert Isolationsfehler schnell und zuverlässig in komplexen isolierten AC/DC-Netzen (IT-Systemen). Eine Einrichtung zur Isolationsfehlersuche, auch IFLS (Insulation Fault Location System) genannt, ermöglicht die schnelle Lokalisierung von Isolationsfehlern in ungeerdeten Stromversorgungssystemen. Sie wird zusätzlich zu einem Isolationswächter eingesetzt und prägt im Fehlerfall einen Prüfstrom zwischen den spannungsführenden Leitern und Erde ein. Im Betrieb erhalten Sie alle notwendigen Informationen über fehlerhafte Stromkreise und Verbraucherabgänge, welche direkt am Isolationsfehlersuchgerät visualisiert werden.

Insulation monitor

Insulation monitoring devices (IMD) are used in unearthed networks (IT networks). The insulation resistance of the network to be monitored is measured against earth. These networks are protected by means of insulation monitors, the use of which is prescribed by law in IT networks by the standard "Safety of Machinery" DIN EN 60204-1 or DIN VDE 0100-410.Insulation monitors serve to prevent accidents in the event of insulation faults, to prevent failures and generally to protect against fire and accidents. Residual current monitors are used for insulation monitoring in earthed systems.

Insulation monitoring

See insulation monitors.

Insulation resistance

The insulation resistance is the resistance in ohms of lines, cables and electrical installations. It is of great importance for the protection of persons against electric shock and the prevention of damage to property. The insulation resistance measurement must be checked periodically according to the DGUV regulation.

Intelligent motor starter

The intelligent motor starters switch and reverse 1- and 3-phase motors up to 4 kW quickly and reliably in a space-saving compact housing with a width of only 22.5 mm. The motor starters combine up to 7 functions in one control cabinet housing and thus enable space savings of up to 80 % compared to the use of conventional devices.