Cookie preferences
This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
"Allow all cookies" cookie
"Decline all cookies" cookie
CSRF token
Cookie preferences
Currency change
Customer recognition
Customer-specific caching
Individual prices
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Show the facebook fanpage in the right blod sidebar
Statistics & Tracking
Affiliate program
Google Tag Manager
Track device being used
Emergency stop module
BN 5930.48/203
- Article number: 0041998
- Type: BN5930.48/203 AC230V 50/60HZ/DC110V
Das BN 5930.48/203, BN 5930.48/204 dient dem sicherheitsgerichteten Unterbrechen eines... more
Product description
Das BN 5930.48/203, BN 5930.48/204 dient dem sicherheitsgerichteten Unterbrechen eines Sicherheitsstromkreises. Es kann zum Schutz von Personen und Maschinen in Anwendungen mit Not-Halt-Tastern und Schutztüren verwendet werden.
Technical specifications
Width: | 100 mm |
Cat. / PL acc. to EN ISO 13849-1: | 4/e |
SIL CL acc. to IEC/EN 62061: | 3 |
Nominal voltage: | AC, DC |
Suited as safety gate monitor: | Yes |
Thermal current Ith max.: | 10 A |
1- / 2-channel: | 1, 2 |
Cross fault detection: | Yes |
Connection: | Pluggable screw terminals |
Output contacts max.: | 1 NC contact, 3 NO contacts |
Type: | BN 5930.48/203 |
Downloads
Advantages
- Can be used for long leads in the e-stop loop. This allows a long distance between e-stop module and the e-stop button.
- Crossfault detection in the e-stop circuit
Features
- According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 - BN 5930.48/203 with cross fault detection by connecting 2 different phases, max. 400 V,
BN 5930.48/204 with cross fault detection by connecting phase and neutral, max. 230 V - Dual voltage version
- Emergency-stop circuit T12, T22: optionally for AC 110 V / DC 60 V or AC 230 V / DC 110 V
- Output: 3 NO, 1 NC contacts for AC 400 V
- 1-channel or 2-channel circuit
- LED displays for channel 1, 2 and mains
- Feedback circuit X1 - X2 for monitoring external contactors
- Removable terminal strips
- Width 100 mm